CHSGB - GRA HI TEMP DRI-FILM GRAPHITE
- MSDS: CHSGB
- Manufacturer: STATE CHEMICAL MFG CO
- Product Name: GRA HI TEMP DRI-FILM GRAPHITE
- National Stock Number: 9150-00N010504
Product Identification
Product ID:GRA HI TEMP DRI-FILM GRAPHITE
MSDS Date:03/01/1996
FSC:9150
NIIN:00N010504
Status Code:A
MSDS Number: CHSGB
Responsible Party
CLEVELAND, OH 44114
US
Emergency Phone: 216-861-7114
Info Phone: 216-861-7114
Cage: 53798
Contractor
Telephone: 216-861-7114
Cage: 53798
Ingredients
PROPANE
CAS: 74-98-6
RTECS: TX2275000
Fraction By Weight: <12%
OSHA PEL 1000 PPM
ACGIH TLV: ASPHYXIANT
ISOBUTANE
CAS: 75-28-5
RTECS: TZ4300000
Fraction By Weight: <12%
OSHA PEL N/K
ACGIH TLV: 1000 PPM (MFR)
HEXANE (N-HEXANE) (CERCLA)
CAS: 110-54-3
RTECS: MN9275000
Fraction By Weight: <50%
OSHA PEL 500 PPM
ACGIH TLV: 50 PPM
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
ISOPROPYL ALCOHOL (SARA 313)
CAS: 67-63-0
RTECS: NT8050000
Fraction By Weight: <30%
OSHA PEL 400 PPM
ACGIH TLV: 400 PPM/500 STEL
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: DIRECT CONTACT WITH EYES OR
SKIN MAY RESULT IN IRRITATION. OVEREXPOSURE TO VAPORS CAN RESULT IN
DIZZINESS, HEADACHE OR NAUSEA. DELIBERATE INHALATION OF VAPORS CAN
BE HARMFUL OR FATAL. CHRONIC: SOLVENTS CAN CAUSE PERMANENT BRAIN
AND NERVOUS SYSTEM DAMAGE. ALSO COULD CAUSE LIVER AND KIDNEY
DISEASE.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:HEXANE MAY DAMAGE PERIPHERAL NERVE
TISSUE (THAT OF THE ARMS AND LEGS) AND RESULT IN MUSCULAR WEAKNESS
AND LOSS OF SENSATION IN EXTREMITIES (PERIPHERAL NEUROPATHY).
First Aid
First Aid:INGEST: DO NOT INDUCE VOMITING. CONTACT PHYS IMMEDIATELY.
INHAL: REMOVE PERSON TO FRESH AIR. IF DIFFICULTY IN BREATHING OR
IRRITATION PERSISTS, CONSULT PHYSICIAN. EYES: FLUSH IMMEDIATELY
WITH PLENTY O F COOL WATER FOR AT LST 15 MINUTES. IF IRRITATION
PERSISTS, CONSULT PHYSICIAN. DO NOT WEAR CONTACT LENSES USING THIS
PRODUCT. SKIN: WASH THOROUGHLY WITH SOAP & WATER. IF IRRIT
DEVELOPS, CONSULT PHYS.
Fire Fighting
Flash Point:<20F,<-7C
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL OR WATER FOG.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . KEEP CONTAINERS COOL. USE SHIELDING TO PROTECT
PERSONNEL FROM VENTING, RUPTURING/BUSTING CONTAINERS.
Unusual Fire/Explosion Hazard:EXPOSURE TO TEMPERATURES ABOVE 120F MAY
CAUSE TO VENT, RUPTURE OR BURST. EXTREMELY FLAMMABLE.
Accidental Release
Spill Release Procedures:REMOVE SOURCES OF HEAT, SPARKS OR FLAME.
VENTILATE AREA OF THE SPILL. ABSORB ON OIL ABSORBENT. FLUSH RESIDUE
WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DANGER: EXTREMELY FLAMM. CONTENT UNDER
PRESS. DO NOT SPRAY NEAR SPARKS, HEAT/OPEN FLAMES. DO NOT STORE IN
DIRECT SUNLIGHT/WHERE TEMPS MAY EXCEED 120F.
Other Precautions:USE W/ADEQ VENT. DO NOT PUNCTURE/INCIN CANS. READ &
FOLLOW ALL LBL DIRECTIONS & PRECAUTIONS BEFORE USING PROD. THESE
PRODUCTS ARE INTENDED FOR INDUST & INSTITUTIONAL USE ONLY. NOT FOR
HOUSEHOLD USE/RE SALE. KEEP OUT OF REACH OF CHILDREN.
Exposure Controls
Respiratory Protection:IF TLV IS EXCEEDED, WEAR NIOSH APPROVED
RESPIRATOR FITTED WITH ORGANIC VAPOR CARTRIDGES.
Ventilation:USE WITH ADEQUATE VENTILATION.
Protective Gloves:VITON GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
% VOLAT BY WT: >90. FL PT: <20F,<-7C PROPELLANT. NO FLASHPOINT BY TOC
FOR CONCENTRATE. POSITIVE FLAME EXTENSION.
Chemical Properties
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:NEGLIGIBLE
Appearance and Odor:A BLACK AEROSOL SPRAY WITH A SOLVENT ODOR.
Percent Volatiles by Volume:SUPDAT
Stability
Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:EXPOSURE TO TEMPERATURES ABOVE 120F.
Hazardous Decomposition Products:BURNING OF THIS PRODUCT MAY RESULT IN
FORMATION OF CARBON MONOXIDE AND CARBON DIOXIDE.
Disposal
Waste Disposal Methods:FOLLOW ALL FEDERAL, STATE AND LOCAL REGULATIONS
REGARDING WASTE DISPOSAL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.