CHYVB - #39999-00G COMPLT SET OF MICROCHEM,SODIUM HYDROXIDE 0.1M

  • MSDS: CHYVB
  • Manufacturer: CENTRAL SCIENTIFIC COMPANY
  • Product Name: #39999-00G COMPLT SET OF MICROCHEM,SODIUM HYDROXIDE 0.1M
  • National Stock Number: 6640-00D007895
Product Identification

Product ID:#39999-00G COMPLT SET OF MICROCHEM,SODIUM HYDROXIDE 0.1M
MSDS Date:03/01/1995
FSC:6640
NIIN:00D007895
Status Code:A
Kit Part:Y
MSDS Number: CHYVB

Responsible Party
CENTRAL SCIENTIFIC COMPANY
11222 MELROSE AVE
FRANKLIN PARK, IL 60131
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 708-451-0150

Preparer: R.M. CARLSON

Cage: CNTRL

Contractor
TRANSPORTATION ONLY
UNKNOW FRANKLIN, PARK, IL 60131 US

Telephone: 708-451-0150

Cage: CENC2

Ingredients

SODIUM HYDROXIDE (CERCLA)

CAS: 1310-73-2

RTECS: WB4900000

Fraction By Weight: 0.40%

OSHA PEL 2 MG/M3

ACGIH TLV: C 2 MG/M3; 9596

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: BALANCE

OSHA PEL NOT RELEVANT

ACGIH TLV: NOT RELEVANT

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CORROSIVE.ACUTE:IRRIT & BURNS TO
SKIN,EYE,LUNGS,MUCOUS MEMBRANES,GI TRACT.CHRONIC:DERMATITIS.
Effects of Overexposure:(WHEN IN DOUBT CALL PHYSICIAN OR LOCAL POISON
CONTROL CENTER). IRRITATION & BURNS TO SKIN,EYES,LUNGS,MUCOUS
MEMBRANES,GI TRACT.DERMATITIS.
Medical Cond Aggravated by Exposure:PERSONS W/PRE-EXISTING SKIN OR EYE
DISORDERS MAY BE MORE SUSCEPTIBLE.

First Aid

First Aid:SKIN:WASH THOROUGHLY W/RUNNING H2O.IRRIT DVLPS GET MED
ADVICE.EYE:WASH W/PLENTY OF H2O FOR @LEAST 15MINS,LIFT EYELIDS
OCCASION.GET MED ATTN IMMED.INHAL:REMOVE TO FRESH AIR.NOT BREATH
GIVE ART RESP;BRE ATH DIFFI GIVE OXY.CALL DR.INGEST:GIVE SEVERAL
GLASSES OF H2O/MILK IF AVAI TO DRINK.VOMIT MAY OCCUR SPONT,BUT DONT
INDUCE!NEVER GIVE ANYTHING BY MOUTH TO UNCONSC PERSON.GET MED ATTN
IMEMD.GIVE(SUPPLE)

Fire Fighting

Flash Point:NA
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:NP
Upper Limits:NP
Extinguishing Media:USE ANY MEDIUM SUITABLE FOR EXTINGUISHING
SUPPORTING FIRE.
Fire Fighting Procedures:IN EVENT OF FIRE WEAR FULL PROTECTIVE CLOTH &
NIOSH-APPROV SELF-CONTAIN BREATH APPARATUS W/FULL FCPIECE OPERATED
IN PRESSURE DEMAND OR OTHER +PRESSURE MODE.
Unusual Fire/Explosion Hazard:NOT CONSIDERED TO BE A FIRE HAZARD.NOT
CONSIDERED TO BE AN EXPLOSION HAZARD.

Accidental Release

Spill Release Procedures:SPILLS:CLEANUP PERSONNEL REQUIRE PROT CLOTH &
RESP PROT FROM MISTS.SM SPILLS CAN BE DILUTED W/LG QUANT OF
H2O,NEUTRALIZED W/DILUTE ACETIC ACID.CAUTION!FLOOR/OTHER SURFS MAY
BE SPLIPPERY.DONT FLUSH WAS TE CAUSTIC DIRECTLY TO SEWER/SURF
H2O.LG(SUPPLEM)
Neutralizing Agent:DILUTE ACETIC ACID.

Handling

Handling and Storage Precautions:STORE IN COOL DRY LOCATION.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NONE NEEDED NORMALLY.
Ventilation:LOCAL EXHAUST AND MECHANICAL(GENERAL).
Protective Gloves:VINYL OR RUBBER.
Eye Protection:GOGGLES
Other Protective Equipment:LAB COAT
Work Hygienic Practices:WASH CONTAMINATED CLOTHING BEFORE
REUSE;THOROUGHLY CLEAN SHOES BEFORE REUSE.
Supplemental Safety and Health
SPILLS:SPILLS CAN BE SHOVELED UP FOR RECOVERY OR DISPO. 1STAID:CITRUS
JUICE TO HELP NEUTRALIZE. PC:39957-00. KEY1:HCC=B1. PER MFG KIT NOT
MANUFACTURED ANY MORE,SIZE=50ML.SEE OTHER PARTS @CAGES:11273,C
ENC1,CENC2,CENC3,CENC4 ALL PNIND W/SAMENSN.

Chemical Properties

HCC:V1
Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Decomp Temp:Decomp Text:NP
Vapor Pres:NA
Vapor Density:NA
Spec Gravity:1
pH:NP
Viscosity:NP
Evaporation Rate & Reference:NA
Solubility in Water:100%
Appearance and Odor:CLEAR COLORLESS SOLUTION, NO ODOR
Percent Volatiles by Volume:NA
Corrosion Rate:NP

Stability

Stability Indicator/Materials to Avoid:YES
ACIDS.
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:NONE KNOWN.

Disposal

Waste Disposal Methods:DISPOSE IN RCRA APPROVED WASTE FACILITY OR SEWER
THE NEUTRALIZED SLURRY W/EXCESS WATER IF LOC ORDINANCES
ALLOW.CLEANUP/DISPOSAL METHODS ARE RECOMMENDATIONS ONLY.CHECK YOUR
LOC/STATE/FED REGS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.