CHYVW - #39999-00G COMPLT SET OF MICROCHEM,SULFURIC ACID 0.5M

  • MSDS: CHYVW
  • Manufacturer: CENTRAL SCIENTIFIC COMPANY
  • Product Name: #39999-00G COMPLT SET OF MICROCHEM,SULFURIC ACID 0.5M
  • National Stock Number: 6640-00D007895
Product Identification

Product ID:#39999-00G COMPLT SET OF MICROCHEM,SULFURIC ACID 0.5M
MSDS Date:03/09/1995
FSC:6640
NIIN:00D007895
Status Code:A
Kit Part:Y
MSDS Number: CHYVW

Responsible Party
CENTRAL SCIENTIFIC COMPANY
11222 MELROSE AVE
FRANKLIN PARK, IL 60131
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 847-451-0150

Preparer: R.M. CARLSON

Cage: CNTRL

Contractor
TRANSPORTATION ONLY
UNKNOW FRANKLIN, PARK, IL 60131 US

Telephone: 708-451-0150

Cage: CENC2

Ingredients

SULFURIC ACID (SARA 302/313) (CERCLA)

CAS: 7664-93-9

RTECS: WS5600000

Fraction By Weight: 2.8%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3/3 STEL; 9596

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: BALANCE

OSHA PEL NOT RELEVANT

ACGIH TLV: NOT RELEVANT

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:IRRITATION AND BURNS TO
SKIN,EYES,MUCOUS MEMBRANES,GI TRACT.CHRONIC:DERMATITIS,RASH.
Effects of Overexposure:(WHEN IN DOUBT CALL PHYSICIAN OR LOCAL POISON
CONTROL CENTER). IRRITATION AND BURNS TO SKIN,EYES,MUCOUS
MEMBRANES,GI TRACT.DERMATITIS,RASH.
Medical Cond Aggravated by Exposure:PERONS W/PRE-EXISTING SKIN
DISORDERS MAY BE MORE SUSCEPTIBLE.

First Aid

First Aid:SKIN:REMOVE ANY CONTAM CLOTH.WASH SKIN W/PLENTY OF H2O @LEAST
15MINS.IRRIT DVLPS GET MED ATTN.EYE:WASH W/PLENTY OF H2O @LEAST
15MINS,LIFT EYELIDS OCCASIONALLY.GET MED ATTN IMMED.INHAL:REMOVE TO
FRESH AIR.NOT BREATH GIVE ART RESP;BREATH DIFFIC GIVE OXY.CALL
DR.INGEST:VOMIT MAY OCCUR SPONT BUT DONT INDUCE!NEVER GIVE ANYTHING
BY MOUTH IF UNCONSC.GET MED ATTN IMMED.GIVE MILK OF MAGNESIA TO
HELP NEUTRA

Fire Fighting

Flash Point:NA
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:NP
Upper Limits:NP
Extinguishing Media:USE ANY MEDIUM SUITABLE FOR EXTINGUISHING
SUPPORTING FIRE.
Fire Fighting Procedures:IN EVENT OF FIRE WEAR FULL PROTECTIVE CLOTH &
NIOSH-APPROV SELF-CONTAIN BREATH APPARATUS W/FULL FCPIECE OPERATED
IN PRESSURE DEMAND OR OTHER +PRESSURE MODE.
Unusual Fire/Explosion Hazard:NOT CONSIDERED TO BE FIRE/EXPLOSION
HAZARD.

Accidental Release

Spill Release Procedures:PROVIDE FORCED VENTI TO DISSIPATE
FUMES.CLEANUP PERSONNEL SHOULD WEAR PROT CLOTH/RESP EQPMT SUITABLE
FOR TOXIC/CORR FLUIDS/VAP.ISOLATE/ENCLOSE IN AREA OF
LEAK/SPILL.SM-FLUSH W/H2O,NEUTRALIZE W/ALKALIN E MATL(SODA
ASH,LIME,ETC).SEWER W/EXCESS H2O(SUPP)
Neutralizing Agent:ALKALINE MATERIAL (SODA ASH, LIME, ETC)

Handling

Handling and Storage Precautions:STORE IN COOL LOCATION.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:ACID VAPOR.
Ventilation:LOCAL EXHAUST AND MECHANICAL(GENERAL).
Protective Gloves:VINYL OR RUBBER.
Eye Protection:GOGGLES/FACESHIELD.
Other Protective Equipment:APRON/LAB COAT
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPILL:LG SPILLS/LOT SIZES-NEUTRALIZE W/ALKALINE MATL,PICKUP W/ABSORBENT
MATL(SAND,EARTH,VERMICULITE). PC:39975-00. KEY1:HCC=C1. PER MFG KIT
NOT MANUFACTURED ANY MORE,SIZE=50ML.SEE OTHER PARTS @CAGES:1
1273,CENC1,CENC2,CENC3,CENC4 ALL PNIND W/SAME NSN.

Chemical Properties

HCC:V1
Boiling Pt:B.P. Text:214F,101C
Melt/Freeze Pt:M.P/F.P Text:35.6F,2.0C
Decomp Temp:Decomp Text:NP
Vapor Pres:NA
Vapor Density:NA
Spec Gravity:>1
pH:NP
Viscosity:NP
Evaporation Rate & Reference:NA
Solubility in Water:100
Appearance and Odor:CLEAR COLORLESS SOLUTION, NO ODOR
Percent Volatiles by Volume:NP
Corrosion Rate:NP

Stability

Stability Indicator/Materials to Avoid:YES
BASES.
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:SUFLUR OXIDES.

Disposal

Waste Disposal Methods:DISPO IN RCRA APPROV WASTE FACI OR SEWER THE
NEUTRALIZED SLURRY W/EXCESS H2O IF LOC ORDINANCES ALLOW.
CLEANUP/DISPOSAL METHODS ARE RECOMMENDATIONS ONLY.CHECK YOUR
LOC/STATE/FED REGS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.