CHYYW - SOLDER FLUX REMOVER; 22-270

  • MSDS: CHYYW
  • Manufacturer: GC THORSEN
  • Product Name: SOLDER FLUX REMOVER; 22-270
  • National Stock Number: 6810-00-602-2347
Product Identification

Product ID:SOLDER FLUX REMOVER; 22-270
MSDS Date:10/22/1996
FSC:6810
NIIN:00-602-2347
Status Code:A
MSDS Number: CHYYW

Responsible Party
GC THORSEN
1801 MORGAN STREET
ROCKFORD, IL 61105
US

Emergency Phone: 815-968-9661;800-424-9300(CHEMTREC)

Info Phone: 815-968-9661;800-435-2931

Cage: EO177

Contractor
TRI CITY ELECTRIC SUPPLY CO
CHESTER, VA 23831-2608 US

Telephone: 804-530-1030

Cage: 63301

Ingredients

METHANE, DICHLORO-; (METHYLENE CHLORIDE) (SARA III)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 82%

OSHA PEL 500 PPM;1000 PPM, C

ACGIH TLV: 50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ISOPROPYL ALCOHOL (SARA III)

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 15%

OSHA PEL 400 PPM;500 PPM STEL

ACGIH TLV: 400 PPM;500 PPM STEL


CARBON DIOXIDE; (CARBON DIOXIDE PROPELLANT)

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: 3%

OSHA PEL 5000 PPM

ACGIH TLV: 5000PPM/30000STEL;93

Fire Fighting

Extinguishing Media:CHEMICAL FOAM, DRY CHEMICAL.
Fire Fighting Procedures:WEAR PRESSURE DEMAND SELF-CONTAINED BREATHING
APPARATUS & FULL PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY YIELD
TOXIC FUMES.

Exposure Controls

Supplemental Safety and Health

Chemical Properties

HCC:V2
Vapor Pres:270
Vapor Density:3.2
Spec Gravity:1.23
Evaporation Rate & Reference:11 (NO REFERENCE)
Solubility in Water:PARTIAL
Appearance and Odor:CLEAR LIQUID - ALCOHOL ODOR
Percent Volatiles by Volume:100
Corrosion Rate:

Stability

Stability Indicator/Materials to Avoid:YES
AL, BA, LI, SN, NAK ALLOYS, TI, STRONG OXIDIZERS.
Stability Condition to Avoid:EXTREME HIGH TEMPERATURES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.