CJDTL - "SUVA" HP62 (R404A)
- MSDS: CJDTL
- Manufacturer: DU PONT E I DE NEMOURS AND CO INC
- Product Name: "SUVA" HP62 (R404A)
- National Stock Number: 6830-01-392-0959
Product Identification
Product ID:"SUVA" HP62 (R404A)
MSDS Date:03/04/1996
FSC:6830
NIIN:01-392-0959
Status Code:A
MSDS Number: CJDTL
Responsible Party
WILMINGTON, DE 19898
US
Emergency Phone: 800-441-3637/800-424-9300(CHEMTREC)
Info Phone: 800-441-3637
Preparer: DUPONT CHEMICALS
Cage: 2S827
Contractor
Telephone: 1-800-441-7515
Cage: 2S827
Ingredients
PENTAFLUOROETHANE,
CAS: 354-33-6
ETHANE, 1,1,1-TRIFLUORO-
CAS: 420-46-2
RTECS: KJ4110000
ETHANE, 1,1,1,2-TETRAFLUORO-
CAS: 811-97-2
Hazards
LD50 LC50 Mixture:THE BLEND IS UNTESTED.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION OF HIGH CONCENTRATIONS OF
VAPOR IS HARMFUL & MAY CAUSE HEART IRREGULARITIES, UNCONSCIOUSNESS,
OR DEATH. INTENTIONAL MISUES OR DELIBERATE INHALATION MAY CAUSE
DEATH WITHOUT WARNING. VAPOR RE DUCES OXYGEN AVAILABLE FOR
BREATHING AND IS HEAVIER THAN AIR. LIQUID CONTACT CAN CAUSE
FROSTBITE.
Explanation of Carcinogenicity:NOT CARCINOGENIC.
Effects of Overexposure:OVEREXPOSURE TO THE VAPORS BY INHALATION MAY
INCLUDE TEMPORARY NERVOUS SYSTEM DEPRESSION WITH ANESTHETIC EFFECTS
SUCH AS DIZZINESS, HEADACHE, CONFUSION, INCOORDINATION AND LOSS OF
CONSCIOUSNESS. HIGHE R EXPOSURES TO THE VAPORS MAY CAUSE TEMPORARY
ALTERATION OF THE HEARTS ELECTRICAL ACTIVITY WITH IRREGULAR PULSE,
PALPITATION, OR INADEQUATE CIRCULATION; OR FATALITY FROM GROSS
OVEREXPOSURE. CONTACT WI TH LIQUID CAN CAUSE FROSTBITE.
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH PREEXISTING
DISEASE OF THE CENTRAL NERVOUS OR CARDIOVASCULAR SYSTEM MAY HAVE
INCREASED SUSCEPTIBILITY TO THE TOXICITY OF INCREASED EXPOSURE.
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR. KEEP PERSON CALM, IF NOT
BREATHING, GIVE ARTIFICIAL RESPIRATION. IF BREATHING IS DIFFICULT,
GIVE OXYGEN. SKIN: FLUSH WITH LUKE WARM WATER. DO NOT USE HOT
WATER. IF FRO STBITE HAS OCCURRED, CALL A PHYSICIAN. EYES:
IMMEDIATELY FLUSH EYES WITH PLENTY OF WATER FOR 15 MINUTES.CALL A
PHYSICIAN. INGESTION: NOT A PROBABLE ROUTE; HOWEVER, INCASE OF
ACCIDENTAL INGESTION, CALL A PHYSICIAN.
Fire Fighting
Flash Point Method:TOC
Extinguishing Media:AS APPROPIATE FOR COMBUSTIBLES IN AREA.
Fire Fighting Procedures:COOL TANKS/CONTAINERS WITH WATER SPRAY. SCBA
APPARATUS MAY BE REQUIRED IF CYLINDERS RUPTURE OR RELEASED UNDER
FIRE CONDITIONS.
Unusual Fire/Explosion Hazard:CYLINDERS MAY REPTURE UNDER FIRE
CONDITIONS. DECOMPOSITION MAY OCCUR.
Accidental Release
Spill Release Procedures:VENTILATE AREA USING FORCED VENTILATION,
ESPECIALLY IN LOW/ENCLOSED PLACES WHERE HEAVY VAPORS MIGHT COLLECT.
REMOVE OPEN FLAMES. USE SELF-CONTAINED BREATHING APPARATUS IF LARGE
SPILL OR LEAK OCCURS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN A CLEAN, DRY PLACE. DO NOT
HEAT ABOVE 52C (126F).
Other Precautions:AVOID BREATHING VAPORS. AVOID LIQUID CONTACT WITH
EYES OR SKIN. USE WITH SUFFCIENT VENTILATION TO KEEP EMPLOYEE
EXPOSURE BELOW THE RECOMMENDED LIMIT.
Exposure Controls
Respiratory Protection:UNDER NORMAL MANUFACTURUNG CONDITIONS, NO
RESPIRATORY PROTECTION IS REQUIRED WHEN USING THIS PRODUCT.
SELF-CONTAINED BREATHING APPARATUS IS REQUIRED IF LARGE RELEASE
OCCURS.
Ventilation:LOCAL EXHAUST IF LARGE AMOUNTS ARE RELEASED. MECHANICAL
VENTILATION SHOULD BE USEDD IN LOW/ENCLOSED PLACES.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING. WASH
CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
NOTE TO PHYSICIAN: BECAUSE OF POSSIBLE DISTURBANCES OF CARDIAC RHYTHM,
CATECHOLAMINE DRUGS, SUCH AS EPINEPHRINE, SHOULD ONLY BE USED
W/SPECIAL CAUTION.
Chemical Properties
HCC:G3
Boiling Pt:=-46.7C, -52.0F
Vapor Pres:182.1 PSIA
Evaporation Rate & Reference:(CARBONTETRACHLORIDE=1)>1
Solubility in Water:0.1 WT%
Appearance and Odor:CLEAR,COLORLESS LIQUIDFIED GAS W/SLIGHT ETNEREAL
ODOR
Percent Volatiles by Volume:100/WT
Stability
Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS-POWDERED ALUMINUM, ZINC, BERYLLIUM.
Stability Condition to Avoid:AVOID OPEN FLAMES AND HIGH TEMPERATURES.
Hazardous Decomposition Products:HYDROCHLORIC AND HYDROFLUORIC ACIDS &
POSSIBLE CARBONYL HALIDES.
Disposal
Waste Disposal Methods:COMPLY WITH FEDERAL, STATE & LOCAL REGULATIONS.
RECLAIM BY DISTILLATION OR REMOVE TO A PERMITTED WASTE DISPOSAL
FACILITY.
Toxicology
Toxicological Information:ANIMAL DATA: THE BLEND IS UNTESTED. HFC-125,
INHALATION 4 HOUR ALC:> 709,000 PPM IN RATS. SINGLE, HIGH
INHALATION EXPOSURES CAUSED LETHARGY, DECREASED ACTIVITY, LABORED
BREATHING AND WEIGHT LOSS.
Ecology
Ecological:AQUATIC TOXICITY: HFC-143A, 96-HOUR LC50, RAINBOW TROUT:>40
MG/L. HFC-134A: 48-HOUR EC50, DAPHNIA MAGNA: 980 MG/L, 96-HOUR
LC50, RAINBOW TROUT: 450 MG/L.
Transport
Transport Information:PROPER SHIPPING NAME: LIQUEFIED GAS, N.O.S.
(PENTAFLUOROETHANE AND TETRAFLUOROETHANE), 2.2, UN 3163,
NONFLAMMABLE GAS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.