CJHTL - CARBON DIOXIDE ELECTRODE INTERNAL FILLING SOLUTION, 950202

  • MSDS: CJHTL
  • Manufacturer: ORION RESEARCH INC
  • Product Name: CARBON DIOXIDE ELECTRODE INTERNAL FILLING SOLUTION, 950202
  • National Stock Number: 6810-00N091190
Product Identification

Product ID:CARBON DIOXIDE ELECTRODE INTERNAL FILLING SOLUTION, 950202
MSDS Date:10/15/1996
FSC:6810
NIIN:00N091190
Status Code:A
MSDS Number: CJHTL

Responsible Party
ORION RESEARCH INC
500 CUMMINGS CENTER
BEVERLY, MA 01915-6199
US

Emergency Phone: 978-922-4400

Info Phone: 978-922-4400

Preparer: S. GLYNN

Cage: 014G6

Contractor
ORION RESEARCH, INC.
BEVERLY, MA 01915-6199 US

Telephone: 978-232-6000

Cage: 014G6

Ingredients

(ORAL,RAT) 4,220 MG/KG.

CAS: 144-55-8

RTECS: VZ0950000


WATER; (DEIONIZED WATER (H*2O))

CAS: 7732-18-5

RTECS: ZC0110000


(ORAL,RAT) 383 MG/KG.

CAS: 7447-40-7

RTECS: TS8050000


(ORAL,RAT) 4,000 MG/KG.

CAS: 9036-19-5

RTECS: MD0907600


SILVER CHLORIDE (AGCL)

CAS: 7783-90-6

RTECS: VW3563000

OSHA PEL 0.01 MG/M3

ACGIH TLV: 0.01 MG/M3

Hazards

LD50 LC50 Mixture:SEE INGREDIENTS.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:NO ADVERSE EFFECTS HAVE BEEN
REPORTED; HOWEVER, MAY CAUSE IRRITATION AND REDNESS ON CONTACT WITH
EYES. CHRONIC:PROLONGED EXPOSURE MAY CAUSE IRRITATION OF SKIN AND
CONJUNCTIVITIS.
Explanation of Carcinogenicity:NOT FOUND ON THESE LISTS.
Effects of Overexposure:RED, IRRITATED SKIN.
Medical Cond Aggravated by Exposure:DISEASES OF THE SKIN,
CONJUNCTIVITIS.

First Aid

First Aid:SKIN:WASH AFFECTED AREA WITH SOAP & LARGE AMOUNTS OF WATER
FOR AT LEAST 15 MINUTES. CONSULT MD. INGESTION: CALL MD IMMEDIATELY
. INHALATION: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF
RESP) . EYE: IMMEDIATELY FLUSH W/POTABLE WATER FOR AT LEAST 15
MINUTES, SEEK ASSISTANCE FROM MD .

Fire Fighting

Extinguishing Media:WATER, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE. NFPA RATING: HEALTH: 1; FIRE: 0;
REACTIVITY: 0; PERSISTENCE: NONE.

Accidental Release

Spill Release Procedures:CLEAN UP AND SET ASIDE FOR WASTE DISPOSAL.

Exposure Controls

Respiratory Protection:NONE. NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST: NONE. MECHANICAL (GENERAL): NONE. SPECIAL:
NONE. OTHER: NONE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER . LAB
COAT.
Supplemental Safety and Health

Chemical Properties

Boiling Pt:=100.C, 212.F
B.P. Text:@ 750 MM HG
Melt/Freeze Pt:=-1.C, 30.2F
Spec Gravity:1.0 (H*2O=1)
pH:8.0-8.5 @ 25C
Evaporation Rate & Reference:N/A (BUTYL ACETATE=1)
Solubility in Water:MISCIBLE (% BY WT)
Appearance and Odor:CLEAR, COLORLESS SOLUTION.
Percent Volatiles by Volume:N/A (WT)

Stability

Stability Indicator/Materials to Avoid:YES
BORON TRIFLUORIDE, (H*2SO*4 + KMNO*4).
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:CO*2 WILL BE GIVEN OFF IF HEATED TO
DECOMPOSITION.

Disposal

Waste Disposal Methods:DISPOSE OF I/A/W ALL FEDERAL, STATE & LOCAL
LAWS.

Toxicology

Toxicological Information:SILVER CHLORIDE - LD50:(IMP,RAT) 2,400 MG/KG.
DEIONIZED WATER - LD50:(ORAL,DOG) 629,000 MG/KG.

Transport

Transport Information:HAZARDOUS SHIPMENT LABELING: DOT: NONE. IATA:
NONE.

Regulatory

SARA Title III Information:THE CHEMICALS IN THIS PRODUCT DO NOT APPEAR
ON ANY OF THE SARA LISTS.
Federal Regulatory Information:COMPONENTS ARE REPORTED IN EPA TSCA
INVENTORY. CHEMICALS WHICH ARE NOT CLASSIFIED AS HAZARDOUS PER U.S.
OSHA GUIDELINES (29 CFR 1915.2 OR 1916.2) WILL NOT NECESSARILY BE
LISTED ON THIS FORM EVEN THOUG H ONE OR MORE MAY BE A CONSTITUENT
OF THIS PRODUCT.
State Regulatory Information:NOT AFFECTED BY CAL PROP 65. CHEMICALS
WHICH ARE NOT CLASSIFIED AS HAZARDOUS PER MASSACHUSETTS SUBSTANCE
LIST (105MR670.000 APPENDIX A) WILL NOT NECESSARILY BE LISTED ON
THIS FORM EVEN THOUGH ONE OR M ORE MAY BE A CONSTITUENT OF THIS
PRODUCT.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.