CJMBR - 2-501070

Product Identification

Product ID:2-501070
MSDS Date:08/09/1988
FSC:3040
NIIN:01-126-8719
Status Code:A
MSDS Number: CJMBR

Responsible Party
PACIFIC SCIENTIFIC INC. HTL ENERGY SYSTEMS DIV.
7073 W. WILLIS RD.,
CHANDLER, AZ 85226
US

Emergency Phone: 602-961-1100

Info Phone: 602-961-1100

Cage: TO276

Contractor
PACIFIC SCIENTIFIC INC. HTL ENERGY SYSTEMS DIV.
CHANDLER, AZ 85226 US

Telephone: 602-961-1100

Cage: TO276

Ingredients

POTASSIUM PERCHLORATE

CAS: 7778-74-7

RTECS: SC9700000

ACGIH TLV: 15 MG/M3 TDUST


ZIRCONIUM POWDER

CAS: 7440-67-7

RTECS: ZH7070000

ACGIH TLV: 5 MG/M3


GRAPHITE

CAS: 7782-42-5

RTECS: MD9659600

OSHA PEL see Table Z-3

ACGIH TLV: 2 MG/M3


VITON-B

Hazards

LD50 LC50 Mixture:UNAVAILABLE AT PRESENT TIME.
Health Hazards Acute and Chronic:TARGET ORGANS: N/P. HUMAN EFFECTS OF
OVEREXPOSURE: CURRENTLY NO INFORMATION AVAILABLE.
Effects of Overexposure:CURRENTLY NO INFORMATION AVAILABLE

First Aid

First Aid:INHALATION: PROLONGED EXPOSURE TO DUST MAY CAUSE IRRITATION
TO SKIN, MUCOUS MEMBRANES, AND EYES. REMOVE TO FRESH AIR.
ADMINISTER OXYGEN IF BREATHING IS DIFFICULT. CONSULT A PHYSICIAN
IMMEDIATELY. EYE CONTACT: FLUSH EYES WITH PLENTY OF WATERFOR 15
MINUTES. CONTACT PHYSICIAN. SKIN CONTACT: WASH SKIN WITH SOAP AND
WATER, REMOVE CONTAMINATED CLOTHING, WASH CLOTHING BEFORE REUSE.
INGESTION: CONTACT PH YSICIAN IMMEDIATELY.

Fire Fighting

Autoignition Temp:>260.C, 500.F
Extinguishing Media:WATER FOG TO EXTINGUISH RESULTING FIRE, AND TO
LOWER TEMPERATURE. FLLOD WITH WATER, DO NOT SMOTHER WITH BLANKET OR
DRY CHEMICAL AS PERCHLORATES SUPPLY THEIR OWN OXYGEN TO FEED A FIRE
Fire Fighting Procedures:MAINTAIN SAFE QUANTITY DISTANCE RELATIONSHIP.

Accidental Release

Spill Release Procedures:FLOOD WITH WATER.

Handling

Handling and Storage Precautions:STORE BETWEEN -60 F AND 160F. PROTECT
FROM ELECTROSTATIC DISCHARGE.

Exposure Controls

Respiratory Protection:NOT REQUIRED IN NON-RUPTURED UNITS.
Ventilation:USE ONLY IN WELL VENTILATED AREAS, 20% TO 65% HUMIDITY.
Eye Protection:SAFETY GLASSES OR EYE SHIELDS.
Other Protective Equipment:SHOES: CONDUCTIVE SHOES, WRIST STATS OR LEG
STATS OVER NON-CONDUCTIVE SHOES.
Supplemental Safety and Health
HCC G3 IS FOR FINISHED PRODUCT. FOR NITROGEN, SEE MG INDUSTRIES, SAME
NSN.

Chemical Properties

HCC:G3
Spec Gravity:(H20=1)
Evaporation Rate & Reference:(=1)
Solubility in Water:SLIGHT
Appearance and Odor:1 3/8" HEX BODY (METAL) X APPROX. 1 5/8" LG - NO
ODOR. DARK GRAY/BLACK POWDER

Disposal

Waste Disposal Methods:DISPOSE OF EXPOSED MATERIAL BY BURNING IN
SUITABLE PIT OR INCINERATOR.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Transport

Transport Information:HELLFIRE BOTTLE P/N 13008160: THIS IS A PART OF
THE HELLFIRE MISSILE. THIS IS CHARGED WITH NITROGEN GAS TO 8000
PSI. IT IS ACTUATED BY A SMALL SQUIB IN THE NECK OF THE BOTTLE.
GAS FLOWS FROM THE PR ESSURE REGULATOR AT A CONTROLLED RATE UPON
ELECTRICAL ACTUATION OF THE SQUIB. THIS BOTTLE WAS SHIPPED
ORIGINALLY ON A DOD CERTIFICATE OF EQUIVALENCY, AY-83-190. THIS
COF WAS SUPERCEDED BY AY-96-183 REV 1 AND 2, PER MANUFACTURER,
DATED APRIL 16, 1999..