CJMFD - "ACTIVATED" CHEMILUMINESCENT PRODUCT ALL COLORS

  • MSDS: CJMFD
  • Manufacturer: OMNIGLOW CORP
  • Product Name: "ACTIVATED" CHEMILUMINESCENT PRODUCT ALL COLORS
  • National Stock Number: 6260-01-335-2870
Product Identification

Product ID:"ACTIVATED" CHEMILUMINESCENT PRODUCT ALL COLORS
MSDS Date:05/02/1997
FSC:6260
NIIN:01-335-2870
Status Code:A
MSDS Number: CJMFD

Responsible Party
OMNIGLOW CORP
96 WINDSOR CT
WEST SPRINGFIELD, MA 01089
US

Emergency Phone: 413-739-8252/800-228-5635 EXT. 162

Info Phone: 413-739-8252

Cage: 0BY83

Contractor
OMNIGLOW CORP
WEST SPRINGFIELD, MA 01089 US

Telephone: 413-739-8252

Cage: 0BY83

Ingredients

TERT-BUTYL ALCOHOL (SARA 313)

CAS: 75-65-0

RTECS: EO1925000

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM, A4; 9596


DIMETHYLPHTHALATE (SARA 313) (CERCLA)

CAS: 131-11-3

RTECS: TI1575000

OSHA PEL 5 MG/M3

ACGIH TLV: 5 MG/M3; 9596

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


DIBUTYL PHTHALATE (SARA 313) (CERCLA)

CAS: 84-74-2

RTECS: TI0875000

OSHA PEL 5 MG/M3

ACGIH TLV: 5 MG/M3; 9596

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


HYDROGEN PEROXIDE (SARA 302)

CAS: 7722-84-1

RTECS: MX0900000

OSHA PEL 1 PPM

ACGIH TLV: 1 PPM; 9596

Hazards

LD50 LC50 Mixture:LD50 (ORAL, RAT) IS >5000 MG/KG.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TARGET ORGANS :EYES. OVEREXPOSURE TO
CHEMICAL INGREDIENTS IS NOT LIKELY TO CAUSE SIGNIFICANT ACUTE TOXIC
EFFECTS. ACUTE- EYE: MAY CAUSE IRRITATION. SKIN: NO SIGNIFICANT
IRRITATION IN ANIMAL TESTING. INHALATION: EXPECTED TO BE A LOW
HAZARD. ORAL: LOW INGESTION HAZARD. CHRONIC- UNKNOWN.
Effects of Overexposure:IRRITATION

First Aid

First Aid:GET MEDICAL HELP IF SYMPTOMS PERSIST. INHALED:MOVE TO FRESH
AIR. EYES:IMMEDIATELY FLUSH WITH WATER FOR 15 MINUTES, HOLDING
EYELIDS OPEN. SKIN:WASH WITH SOAP & WATER. ORAL:GET MEDICAL
ATTENTION.

Fire Fighting

Flash Point Method:CC
Flash Point:>93.3C, 200.F
>200F,>93C
Extinguishing Media:WATER SPRAY, CARBON DIOXIDE, FOAM OR DRY CHEMICAL.
USE WATER SPRAY TO COOL FIRE EXPOSED CONTAINERS.
Fire Fighting Procedures:WEAR PROTECTIVE CLOTHING AND NIOSH-APPROVED
SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:NOT KNOWN

Accidental Release

Spill Release Procedures:ABSORB SPILL WITH INERT MATERIAL SUCH AS
VERMICULITE. PLACE IN A CONTAINER FOR DISPOSAL. CLEAN AREA
THOROUGHLY WITH WATER TO REMOVE RESIDUAL CONTAMINATION.
Neutralizing Agent:NOT RELEVANT

Handling

Handling and Storage Precautions:NONE REQUIRED.
Other Precautions:WASH HANDS BEFORE EATING OR DRINKING.

Exposure Controls

Respiratory Protection:NONE SHOULD BE NEEDED UNDER NORMAL IF PEL
EXCCEDS, WEAR SELF CONTAINED BREATHING APPARATUS & PROTECTIVE
CLOTHING.
Ventilation:NONE SHOULD BE NEEDED.
Protective Gloves:RUBBER RECOMMENDED
Eye Protection:SAFETY GLASSES
Other Protective Equipment:EYE BATH, WASHING FACILITY
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES.
Supplemental Safety and Health
THE PRODUCT IS AN ARTICLE, CHEMICALS ARE SEALED AND THERE IS NO DANGER
OF OVEREXPOSURE UNDER NORMAL USE.

Chemical Properties

HCC:N1
NRC/State Lic Num:NOT RELEVANT
Decomp Temp:Decomp Text:NOT KNOWN
Spec Gravity:NOT RELEVANT
Evaporation Rate & Reference:NOT RELEVANT
Solubility in Water:NOT RELEVANT
Appearance and Odor:THIS IS AN ARTICLE (PLASTIC TUBE CONTAINING GLASS
AMPOULE W/OXALATE+ACTIVATOR )

Stability

Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE MAY BE
FORMED.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE
AND FEDERAL REGULATIONS.

Transport

Transport Information:NOT REGULATED.

Regulatory

SARA Title III Information:THE FOLLOWING COMPONENTS ARE DEFINED AS
TOXIC CHEMICALS SUBJECT TO REPORTING REQUIREMENT OF SEC 311 OF
TITLE III AND 40 CFR 372 OR EPA REGS: T-BUTANOL: NO TPQ & RQ,
TSCA=YES; DIBUTYL PHTHALATE: NO TPQ , RQ=10 LBS, SEC 313 &
TSCA=YES, RCRA U069; DIMETHYL PHTHALATE: NO TPQ, RQ=5000 LBS, SEC
311&TSCA = YES, RCRA U102.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.