CJMLM - 1905 COLONIAL BLUE, K01905
- MSDS: CJMLM
- Manufacturer: KRYLON HARDWARE
- Product Name: 1905 COLONIAL BLUE, K01905
- National Stock Number: 8010-00N091580
Product Identification
Product ID:1905 COLONIAL BLUE, K01905
MSDS Date:01/14/1998
FSC:8010
NIIN:00N091580
Status Code:A
MSDS Number: CJMLM
Responsible Party
SOLON, OH 44139
US
Emergency Phone: 216-566-2917
Info Phone: 800-832-2541
Cage: 09800
Contractor
Telephone: 216-292-7400 OR 216-595-8634
Cage: 09800
Ingredients
760
CAS: 74-98-6
RTECS: TX2275000
OSHA PEL 1800 MG/M3;1000 PPM
760
CAS: 106-97-8
RTECS: EJ4200000
ACGIH TLV: 1900 MG/M3;800 PPM
7.10
CAS: 100-41-4
RTECS: DA0700000
OSHA PEL 435 MG/M3;100 PPM
ACGIH TLV: 434 MG/M3;100 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
5.90
CAS: 1330-20-7
RTECS: ZE2100000
ACGIH TLV: 434 MG/M3;100 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
5.50
CAS: 71-36-3
RTECS: EO1400000
OSHA PEL 300 MG/M3;100 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
180
CAS: 67-64-1
RTECS: AL3150000
OSHA PEL 2400 MG/M3;1000 PPM
ACGIH TLV: 1780 MG/M3;750 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
70
CAS: 78-93-3
RTECS: EL6475000
OSHA PEL 590 MG/M3;200 PPM
ACGIH TLV: 590 MG/M3;200 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
16
CAS: 108-10-1
RTECS: SA9275000
OSHA PEL 410 MG/M3;100 PPM
ACGIH TLV: 205 MG/M3;50 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
1-METHOXY-2-PROPYL ACETATE; (1-METHOXY-2-PROPANOL ACETATE)
CAS: 108-65-6
RTECS: AI8925000
BARIUM SULFATE
CAS: 7727-43-7
RTECS: CR0600000
OSHA PEL 15 MG/M3
ACGIH TLV: 10 MG/M3
TITANIUM DIOXIDE
CAS: 13463-67-7
RTECS: XR2275000
OSHA PEL 15 MG/M3
ACGIH TLV: 10 MG/M3
BARIUM
CAS: 7440-39-3
RTECS: CQ8370000
ACGIH TLV: 0.5 MG/M3
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EXPOS MAY BE BY INHAL &/OR SKIN OR EYE
CNTCT, DEPENDING ON CNDTNS OF USE. TO MINIMIZE EXPOS, FOLLOW RECOMS
FOR PROPER USE, VENT & PERSONAL PROT EQUIP. ACUTE: IRRIT OF EYES,
SKIN & RESP SYSTEM. MAY CAU SE NERVOUS SYSTEM DEPRESS. EXTREME
OVEREXP MAY RSLT IN UNCON & POSSIBLY DEATH. HDCH, DIZZ, NAUS & LOSS
OF COORD ARE INDICATIONS OF EXCESSIVE EXPOS TO VAPS OR SPRAY MISTS.
REDNESS & ITCHING OR BURNING SENSATION MAY INDICATE EYE OR
EXCESSIVE SKIN EXPOS. CHRONIC: NO INGRED IN THIS PROD IS AN IARC,
NTP OR OSHA LISTED CARCINOGEN. METHYL ETHYL KETONE MAY INCREASE THE
NERVOUS SYSTEM EFTS OF OTHER SOLVENT S. PRLNGD OVEREXP TO (EFTS OF
OVEREXP)
Effects of Overexposure:HLTH HAZS: SOLVENT INGREDS LISTED MAY CAUSE
ADVERSE EFTS TO THE LIVER, URINARY, BLOOD FORMING & REPRODUCTIVE
SYSTEMS. RATS EXPOSED TO TITANIUM DIOXIDE DUST AT 250 MG/M3
DEVELOPED LUNG CANCER, HOWEVER, SUCH EXPOSURE LEVELS ARE NOT
ATTAINABLE IN THE WORKPLACE. REPORTS HAVE ASSOCIATED RPTD & PRLNGD
OVEREXP TO SOLVENTS W/PERM BRAIN & NERVOUS SYSTEM DAMAGE.
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.
First Aid
First Aid:INHALATION: IF AFFECTED, REMOVE FROM EXPOSURE. RESTORE
BREATHING. KEEP WARM AND QUIET. SKIN: WASH AFFECTED AREA THOROUGHLY
WITH SOAP AND WATER. REMOVE CONTAMINATED CLOTHING AND LAUNDER
BEFORE REUSE. E YES: FLUSH EYES WITH LARGE AMOUNTS OF WATER FOR AT
LEAST 15 MINUTES. GET MEDICAL ATTENTION. INGESTION: NEVER GIVE
ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. DO NOT INDUCE VOMITING.
GIVE CONSCIOUS PAT IENT SEVERAL GLASSES OF WATER. SEEK MEDICAL
ATTENTION.
Fire Fighting
Flash Point:<-17.8C, 0.F
Lower Limits:1.0%
Upper Limits:13.1%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . WATER SPRAY MAY BE INEFFECTIVE. IF WATER IS USED, FOG
NOZZLES ARE PREFERABLE. WATER MAY BE USED TO COOL CLOSED CONTAINERS
TO PREVENT PRESS URE BUILD-UP AND POSSIBLE AUTOIGNITION OR
EXPLOSION WHEN EXPOSED TO EXTREME HEAT.
Unusual Fire/Explosion Hazard:ISOLATE FROM HEAT, ELECTRICAL EQUIPMENT,
SPARKS & OPEN FLAME. CLOSED CONTAINERS MAY EXPLODE WHEN EXPOSED TO
EXTREME HEAT. APPLICATION TO HOT SURFACES REQUIRES SPECIAL
PRECAUTIONS. DURING EMERGENCY CON DITIONS OVEREXPOSURE TO
DECOMPOSITION PRODUCTS MAY CAUSE A HEALTH HAZARD. SYMPTOMS MAY NOT
BE IMMEDIATELY APPARENT.
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Handling
Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS & OPEN
FLAME. VAPS WILL ACCUMULATE READILY & MAY IGNITE EXPLOSIVELY.
DURING USE & UNTIL ALL VAPS ARE GONE: KEEP AREA VENTD - DO NOT
SMOKE - EXTINGUISH ALL FLAMES, PILOT LIG HTS, & HEATERS - TURN OFF
STOVES, ELEC TOOLS & APPLIANCES & ANY OTHER SOURCES OF IGNIT.
(SUPDAT)
Other Precautions:INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING AND
INHALING THE CONTENTS CAN BE HARMFUL OR FATAL. USE ONLY WITH
ADEQUATE VENTILATION. AVOID BREATHING VAPOR AND SPRAY MIST. AVOID
CONTACT WITH SKIN AN D EYES. WASH HANDS AFTER USING.
Exposure Controls
Respiratory Protection:USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOC EXHST PREF. GEN EXHST ACCEPTABLE IF EXPOS TO LISTED
MATLS IS MAINTAINED BELOW APPLIC EXPOS LIMS. REFER TO OSHA STDS
1910.94, 1910.107, 1910.108.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EYE WASH AND DELUGE SHOWER MEETING ANSI
DESIGN CRITERIA .
Supplemental Safety and Health
HNDLG/STOR PRECS: CONSULT NFPA CODE. USE APPRVD BONDING & GROUNDING
PROCS. CONTENTS UNDER PRESS. DO NOT PUNCTURE, INCIN OR EXPOSE TO
TEMP ABOVE 120F. HEAT FROM SUNLIGHT, RADIATORS, STOVES, HOT WATER &
OTHER HEAT SOURCES COULD CAUSE CNTNR TO BURST. DO NOT TAKE
INTERNALLY. KEEP OUT OF REACH OF CHILDREN.
Chemical Properties
Boiling Pt:<150.C, 302.F
B.P. Text:<0-302F
Vapor Pres:SEE INGREDS
Vapor Density:HVR/AIR
Spec Gravity:0.79
Evaporation Rate & Reference:FASTER THAN ETHER
Percent Volatiles by Volume:91
Stability
Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:BY FIRE: CARBON DIOXIDE, CARBON
MONOXIDE, OXIDES OF METALS IN INGREDIENT SECTION.
Disposal
Waste Disposal Methods:WASTE FROM THIS PRODUCT MAY BE HAZARDOUS AS
DEFINED UNDER THE RESOURCE CONSERVATION AND RECOVERY ACT (RCRA) 40
CFR 261. WASTE MUST BE TESTED FOR IGNITABILITY& EXTRACTABILITY TO
DETERMINE THE APPLICABL E EPA HAZARDOUS WASTE NUMBERS. DO NOT
INCINERATE. DEPRESSURIZE CONTAINER. DISPOSE OF I/A/W FEDERAL,
STATE & LOCAL REGULATIONS REGARDING POLLUTION.
Other Information
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Regulatory
SARA Title III Information:SARA 313 (40 CFR 372.65C) SUPPLIER
NOTIFICATION: 100-41-4 ETHYLBENZENE 3% BY WT; 1330-20-7 XYLENE 16%
BY WT.
Federal Regulatory Information:ALL CHEMICALS IN THIS PRODUCT ARE
LISTED, OR ARE EXEMPT FROM LISTING, ON THE TSCA INVENTORY.
State Regulatory Information:CALIFORNIA PROPOSITION 65 - WARNING: THIS
PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO
CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.