CJPCW - AMMONIA ELECTRODE FILLING SOLUTION, 951202

  • MSDS: CJPCW
  • Manufacturer: ORION RESEARCH INC
  • Product Name: AMMONIA ELECTRODE FILLING SOLUTION, 951202
  • National Stock Number: 6850-00N072102
Product Identification

Product ID:AMMONIA ELECTRODE FILLING SOLUTION, 951202
MSDS Date:03/05/1999
FSC:6850
NIIN:00N072102
Status Code:A
MSDS Number: CJPCW

Responsible Party
ORION RESEARCH INC
500 CUMMINGS CENTER
BEVERLY, MA 01915-6199
US

Emergency Phone: 978-232-6000

Info Phone: 978-922-4400

Cage: 014G6

Contractor
ORION RESEARCH, INC.
BEVERLY, MA 01915-6199 US

Telephone: 978-232-6000

Cage: 014G6

Ingredients

1.650 MG/KG

CAS: 12125-02-9

RTECS: BP4550000

OSHA PEL 10 MG/M3

ACGIH TLV: 10 MG/M3 FUME

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


WATER; (DEIONIZED WATER (H*20)

CAS: 7732-18-5

RTECS: ZC0110000

Hazards

LD50 LC50 Mixture:SEE INGREDIENT 1.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION OF LARGE DOSES MAY CAUSE
NAUSEA, VOMITING, ACIDOSIS. BECAUSE OF LOW CONCENTRATION OF SALT
(LESS THAN 1%), THIS PRODUCT IS A LOW CHRONIC OR ACUTE HEALTH RISK.
Explanation of Carcinogenicity:NOT FOUND ON THESE LISTS.
Effects of Overexposure:COUGH, NAUSEA, IRRITATION OF STOMACH.
Medical Cond Aggravated by Exposure:STOMACH AILMENTS IF INGESTED.

First Aid

First Aid:INGESTION: CALL MD IMMEDIATELY . INHALATION: REMOVE TO FRESH
AIR. SUPPORT BREATHING (GIVE OXYGEN OR ARTIFICIAL RESPIRATION) .
EYES: IMMEDIATELY FLUSH WITH POTABLE WATER FOR A MINIMUM OF 15
MINUTES, SEEK ASSISTANCE FROM MD . SKIN: WASH AFFECTED AREAS WITH
WATER.

Fire Fighting

Flash Point:NOT FLAMMABLE
Extinguishing Media:ANY. MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:NONE. WEAR NIOSH APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:DILUTE AND WIPE UP SPILL AREA WITH WATER.

Handling

Handling and Storage Precautions:SUITABLE FOR ANY GENERAL STORAGE. KEEP
CLOSURE SEALED TO PROTECT PRODUCT INTEGRITY. NFPA RATINGS: SCALE
(0-4); HEALTH-1, FIRE-0, REACTIVITY-0, SPECIFIC-0.

Exposure Controls

Respiratory Protection:NONE. USE NIOSH APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:NONE.
Protective Gloves:NONE. IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:NONE. ANSI APPROVED EMERGENCY EYE WASH AND
DELUGE SHOWER .
Work Hygienic Practices:NO EATING OR DRINKING WHEN WORKING WITH THIS
PRODUCT.
Supplemental Safety and Health

Chemical Properties

Boiling Pt:=100.C, 212.F
Melt/Freeze Pt:=0.C, 32.F
Spec Gravity:1.0 (H*2O=1)
pH:@ 25C 5-8
Solubility in Water:MISCIBLE (% BY WT)
Appearance and Odor:COLORLESS, ODORLESS LIQUID.

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZERS, HYPOCHLORITE BLEACHES.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:AMMONIA GAS WHEN MADE BASIC.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:OBSERVE ALL FEDERAL, STATE AND LOCAL LAWS WHEN
DISPOSING OF THIS PRODUCT.

Transport

Transport Information:HAZARDOUS: SHIPMENT LABELING: DOT AND LATA: NONE.

Regulatory

SARA Title III Information:SARA TITLE III: NH*4CL IS A CERCLA HAZARD
AND IS SUBJECT TO SECTIONS 304, 311, AND 312 OF THIS LAW.
Federal Regulatory Information:COMPONENTS ARE LISTED IN EPA TSCA
INVENTORY.
State Regulatory Information:NOT FOUND ON CAL PROP 65 LISTING.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.