Product ID:UNI-PAINT MARKERS, PX-21
MSDS Date:06/14/1999
FSC:NIIN:Submitter:N EN
Status Code:A
MSDS Number: CJVLN

Responsible Party
SANFORD CORP
2740 WASHINGTON BLVD
BELLWOOD, IL 60104
US

Emergency Phone: 800-323-0749

Info Phone: 800-228-5635

Preparer: JAMIE PAULIN

Cage: 86874

Contractor
SANFORD CORPORATION
BELLWOOD, IL 60104 US

Telephone: 1-800-323-0749

Cage: 86874

Ingredients

XYLENE

CAS: 1330-20-7

RTECS: ZE2100000

ACGIH TLV: 434 MG/M3;100 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: AT HIGH VAPOR CONCENTRATION -
DIZZINESS, DROWSINESS, AN UNCONSCIOUSNESS MAY OCCUR. CAUTION:
CONTAINS XYLENE. HARMFUL OR FATAL IF SWALLOWED. IF SWALLOWED DO NOT
INDUCE VOMITING. CALL A PHYSICIAN . KEEP OUT OF REACH OF CHILDREN.
USE IN WELL VENTILATED AREA. DIRECT CONTACT MAY CAUSE SKIN OR EYE
IRRITATION.
Effects of Overexposure:SEE HEALTH HAZARDS.

First Aid

First Aid:INHALATION: MOVE PERSON TO FRESH AIR AND SUPPLY ARTIFICAL
RESPIRATION. EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. SKIN:
WASH WITH SOAP AND WATER. INGESTION: DO NOT INDUCE VOMITING - SEE
PHYSICIAN .

Fire Fighting

Flash Point Method:CC
Flash Point:=34.4C, 93.9F
Lower Limits:1.1%
Upper Limits:6.4%
Extinguishing Media:CO*2 OR CHEMICAL FOAM.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . DO NOT USE WATER.
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:TREAT AS FLAMMABLE SOLVENT. USE ADEQUATE
VENTILATION.

Handling

Handling and Storage Precautions:KEEP FROM OPEN FLAMES.
Other Precautions:NONE.

Exposure Controls

Respiratory Protection:NONE REQUIRED IF USED AS INTENDED. NIOSH
APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:YES.
Protective Gloves:NONE REQUIRED IF USED AS INTENDED. IMPERVIOUS GLOVES
.
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EYE WASH AND DELUGE SHOWER MEETING ANSI
DESIGN CRITERIA .
Supplemental Safety and Health
HMIS CODE: HEALTH: 2, FLAMMABILITY 3. REACTIVITY 0. PERSONAL
PROTECTION: N/A.

Chemical Properties

Boiling Pt:=140.C, 284.F
Vapor Pres:(MM HG): 100 MM
Spec Gravity:0.89-0.91
Solubility in Water:INSOLUBLE
Appearance and Odor:CONTAIN COLORED LIQUID INK - XYLENE ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:NONE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL
REGULATIONS.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Regulatory

Federal Regulatory Information:SANFORD CORPORATION HAS BEEN ADVISED BY
COUNCIL THAT THE OSHA HAZARD COMMUNICATION STANDARD DOES NOT APPLY
TO THE SANFORD PRODUCT DESCRIBED IN THIS MSDS. THE REASON FOR THE
EXEMPTION IS CONTAINED IN 29 CFR, PART 1910.1200, (B) (6) (IX), AS
AMENDED JULY 1, 1994 PER THE CODE OF FEDERAL REGULATIONS. THE
INFORMATION CONTAINED IN THE MSDS IS FORWARDED TO YOU FOR YOUR
INFORMATION BUT IS NOT MEANT TO IM PLY THAT THE PRODUCT IS COVERED
BY THE HAZARD COMMUNICATION STANDARD NOR IS THE MSDS MEANT TO
COMPLY WITH ALL REQUIREMENTS OF THE HAZARD COMMUNICATION STANDARD.