CJVTL - A-1318, 5-(AND-6)-((N-(5-AMINOPENTYL) AMINO) (SUPDAT)
- MSDS: CJVTL
- Manufacturer: MOLECULAR PROBES INC
- Product Name: A-1318, 5-(AND-6)-((N-(5-AMINOPENTYL) AMINO) (SUPDAT)
- National Stock Number: 6810-00N092873
Product Identification
Product ID:A-1318, 5-(AND-6)-((N-(5-AMINOPENTYL) AMINO) (SUPDAT)
MSDS Date:08/01/1998
FSC:6810
NIIN:00N092873
Status Code:A
MSDS Number: CJVTL
Responsible Party
EUGENE, OR 97402-9165
US
Emergency Phone: 541-465-8300
Info Phone: 541-465-8300
Cage: 0UCT9
Contractor
Telephone: 541-465-8300
Cage: 0UCT9
Ingredients
5-(AND-6)-((N-(5-AMINOPENTYL) AMINO) CARBONYL)
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MANUFACTURER IS NOT AWARE OF ANY
TOXICITY DATA FOR THIS PRODUCT. MANUFACTURER IS NOT AWARE OF ANY
REPORTED HEALTH HAZARDS FOR THIS PRODUCT. RECOMMENDS TREATING ALL
CHEMICALS WITH CAUTION. TO MANUFACTU RER'S KNOWLEDGE, THE HEALTH
HAZARDS HAVE NOT BEEN THOROUGHLY INVESTIGATED. CARCINOGENICITY: NOT
LISTED BY NTP, IARC OR OSHA.
Effects of Overexposure:UNKNOWN. HANDLE WITH CARE.
First Aid
First Aid:POTENTIALLY HARMFUL; AVOID PROLONGED OR REPEATED EXPOSURE.
WASH THOROUGHLY AFTER HANDLING. EYES: IF EYE CONTACT OCCURS, WASH
AFFECTED AREAS WITH WATER FOR AT LEAST 15 MINUTES AND SEEK MEDICAL
ADVICE. SKIN: IF SKIN CONTACT OCCURS, WASH AFFECTED AREAS WITH
WATER FOR 15 MINUTES AND SEEK MEDICAL ADVICE. INHALATION: IF
INHALED, REMOVE INDIVIDUAL TO FRESH AIR AND SEEK MEDICAL ADVICE.
INGESTION: IF SWALL OWED, SEEK MEDICAL ADVICE.
Fire Fighting
Flash Point:NOT DETERMINED
Extinguishing Media:USE CARBON DIOXIDE, DRY CHEMICAL EXTINGUISHERS OR
WATER.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Accidental Release
Spill Release Procedures:USE APPROPRIATE PROTECTIVE EQUIPMENT AND
METHODS TO CLEAN UP SPILLED SUBSTANCE PROMPTLY. ABSORB SPILL ONTO
APPROPRIATE MATERIAL. COLLECT & DISPOSE OF ALL WASTE IN ACCORDANCE
WITH ALL APPLICABLE LAWS.
Handling
Handling and Storage Precautions:GLOVES, PROTECTIVE CLOTHING AND
EYEWEAR SHOULD BE WORN AND SAFE LABORATORY PRACTICES FOLLOWED.
Exposure Controls
Respiratory Protection:NIOSH APPROVED RESPIRATORY PROTECTION IS
RECOMMENDED.
Ventilation:MECHANICAL VENTILATION IS RECOMMENDED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EYE WASH AND DELUGE SHOWER MEETING ANSI
DESIGN CRITERIA . PROTECTIVE CLOTHING SHOULD BE WORN.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO: CARBONYL)TETRAMETHYLRHODAMINE
(TETRAMETHYLRHODAMINE CADAVERINE). PRODUCT IDENTITY INFORMATION:
UNIT SIZE: 10 MG. MOLECULAR FORMULA: C*30H*34N*4O*4. MOLECULAR
WEIGHT: 514.62.
Chemical Properties
Solubility in Water:LOW
Appearance and Odor:PURPLE SOLID.
Stability
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:NOT A SIGNIFICANT HAZARD IN THESE
QUANTITIES. DESICCATION STORAGE RECOMMENDED. PROTECT MATERIAL FROM
LIGHT, ESPECIALLY IN SOLUTION.
Disposal
Waste Disposal Methods:COLLECT AND DISPOSE OF ALL WASTE IN ACCORDANCE
WITH APPLICABLE FEDERAL, STATE AND LOCAL LAWS.
Toxicology
Toxicological Information:MFR IS NOT AWARE OF ANY TOXICITY DATA FOR
THIS PRODUCT. HOWEVER, HYDROXYLAMINE HYDROCHLORIDE HAS BEEN FOUND
TO HAVE AN ORAL MOUSE LD50 OF 408 MG/KG, AND HAS BEEN SHOWN TO
CAUSE GENE MUTATIONS IN MOUSE LYMPHOCYTES AT 31 MG/L.
Other Information
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ecology
Ecological:ENVIRONMENTAL FATE: WHEN RELS INTO SOIL, THIS MATL IS
EXPECTED TO LEACH INTO GROUNDWATER. WHEN RELS INTO THE SOIL, THIS
MATL MAY BIODEGRADE TO MOD EXTENT. WHEN RELS INTO SOIL, THIS MATL
IS NOT EXPECTE D TO EVAP SIGNIFICANTLY. THIS MATL IS NOT EXPECTED
TO SIGNIFICANTLY BIOACCUMULATE. WHEN RELS INTO AIR, THIS MATL IS
EXPECTED TO BE READILY DEGRADED BY PHOTOLYSIS. ENVIRONMENTAL TOX:
THIS MATL IS NOT E XPECTED TO BE TOXIC TO AQUATIC LIFE. THE
LC50/96-HOUR VALUES FOR FISH ARE OVER 100 MG/L.
Transport
Transport Information:NOT REGULATED.
Regulatory
Federal Regulatory Information:THIS MATERIAL IS SOLD FOR RESEARCH
PURPOSES ONLY AND IS NOT REQUIRED TO APPEAR ON THE TSCA INVENTORY.
State Regulatory Information: