CJYPM - AIR BLASTER, 21995

Product Identification

Product ID:AIR BLASTER, 21995
MSDS Date:07/28/1999
FSC:7930
NIIN:00N093433
Status Code:A
MSDS Number: CJYPM

Responsible Party
BOWMAN DISTRIBUTION, BARNES GROUP INC
1301 EAST 9TH ST, SUITE 700
CLEVELAND, OH 44114-1824
US

Emergency Phone: 303-623-5716

Info Phone: 216-416-7200

Cage: 05573

Contractor
BOWMAN DISTRIBUTION, BARNES GROUP INC
CLEVELAND, OH 44114-1824 US

Telephone: 216-416-7200

Cage: 05573

Ingredients

760.

CAS: 75-37-6

RTECS: KI1410000

OSHA PEL 65

ACGIH TLV: N/E


760.

CAS: 115-10-6

RTECS: PM4780000

OSHA PEL 35

ACGIH TLV: N/E

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ROUTES OF EXPOSURE: EXPOSURE MAY BE BY
INHALATION AND/OR SKIN OR EYE CONTACT, DEPENDING ON CONDITIONS OF
USE. TO MINIMIZE EXPOSURE, FOLLOW RECOMMENDATIONS FOR PROPER USE,
VENTILATION, AND PERSONAL PRO TECTIVE EQUIPMENT. ACUTE: IRRITATION
OF EYES, SKIN AND RESPIRATORY SYSTEM. MAY CAUSE NERVOUS SYSTEM
DEPRESSION. EXTREME OVEREXPOSURE MAY RESULT IN UNCONSCIOUSNESS AS
POSSIBLY DEATH. CHRONIC: NO INGRED IENT IN THIS PRODUCT IS AN IARC,
NTP OR OSHA LISTED CARCINOGEN. REPORTS HAVE ASSOCIATED REPEATED AND
PROLONGED OVEREXPOSURE TO SOLVENTS WITH PERMANENT BRAIN AND NERVOUS
SYSTEM DAMAGE.
Effects of Overexposure:HEADACHE, DIZZINESS, NAUSEA, AND LOSS OF
COORDINATION ARE INDICATIONS OF EXCESSIVE EXPOSURE TO VAPORS OR
SPRAY MISTS. REDNESS AND ITCHING OR BURNING SENSATION MAY INDICATE
EYE OR EXCESSIVE SKIN EXPOSU SRE.
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.

First Aid

First Aid:INHALATION: IF AFFECTED, REMOVE FROM EXPOSURE. RESTORE
BREATHING. KEEP WARM AND QUIET. SKIN: WASH AFFECTED AREA THOROUGHLY
WITH SOAP AND WATER. REMOVE CONTAMINATED CLOTHING AND LAUNDER
BEFORE RE-USE. EYES: FLUSH WITH LARGE AMOUNTS OF WATER FOR AT
LEAST 15 MINUTES. GET MEDICAL ATTENTION. INGESTION: GET MEDICAL
ATTENTION.

Fire Fighting

Flash Point:<-17.6C, 0.F
Lower Limits:27.0%
Upper Limits:3.4%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . WATER SPRAY MAY BE INEFFECTIVE. IF WATER IS USED, FOG
NOZZLES ARE PERFERABLE. WATER MAY BE USED TO COOL CLOSED CONTAINERS
TO PREVENT PRESSUR E BUILD-UP AND POSSIBLE AUTOIGNITION OR
EXPLOSION WHEN EXPOSED TO EXTREME HEAT.
Unusual Fire/Explosion Hazard:RISKS OF EXPLOSION: ISOLATE FROM HEAT,
ELECTRICAL EQUIP, SPARKS, & OPEN FLAME. CLOSED CONTAINERS MAY
EXPLODE WHEN EXPOSED TO EXTREME HEAT. APPLICATION TO HOT SURFACES
REQUIRES SPECIAL PREC. DURING EME R CONDITIONS OVEREXPOSURE TO
DECOMP PRODS MAY CAUSE HLTH HAZARD. SYMPTOMS MAY NOT BE IMMED
APPARENT. OBTAIN MED ATTN.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.

Handling

Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS & OPEN
FLAME. VAPORS WILL ACCUMULATE READILY & MAY IGNITE EXPLOSIVELY.
DURING USE & UNTIL ALL VAPS ARE GONE: KEEP AREA VENTILATED-DO NOT
SMOKE-EXTINGUISH ALL FAMES, PILOT L IGHTS, & HEATERS-TURN OFF
STOVES, ELECTRIC TOOLS & APPLIANCES, & ANY OTHER SOURCES OF
IGNITION.
Other Precautions:CONSULT NFPA CODE. USE APPROVED BONDING & GROUNDING
PROCEDURES. CONTENTS UNDER PRESSURE. DO NOT PUNCTURE,
INCINERATE/EXPOSE TO TEMPERATURES ABOVE 120F. HEAT FROM SUNLIGHT,
RADIATORS, STOVES, HOT WATER , & OTHER HEAT SOURCES COULD CAUSE
CONTAINER TO BURST. DO NOT TAKE INTERNALLY. KEEP OUT OF REACH OF
CHILDREN. (SUPDAT)

Exposure Controls

Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW
APPLICABLE LIMITS BY VENTILATION, WEAR A PROPERLY FITTED ORGANIC
VAPOR/PARTICULATE RESPIRATOR APPROVED BY NIOSH FOR PROTECTION
AGAINST MATERIALS IN SECT ION 2.
Ventilation:LOC EXHT PREF. GEN EXHST ACCEPTABLE IF EXPOS TO MATLS IN
SECTION 2 IS MAINTAINED BELOW APPLIC EXPOS LIMITS. REFER TO OSHA
STDS 1910.94, 1910.107, 1910.108.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH AND DELUGE SHOWER .
Work Hygienic Practices:WASH HANDS AFTER USING. PRECAUTIONS TO BE TAKEN
IN USE: USE ONLY WITH ADEQUATE VENTILATION. AVOID BREATHING VAPOR
AND SPRAY MIST. AVOID CONTACT WITH SKIN AND EYES.
Supplemental Safety and Health
PHYSICAL DATA: VOLATILE ORGANIC COMPOUND BY WEIGHT: 35%. VOLATILE
ORGANIC COMPOUND BY VOL: 100%. ODOR THRESHOLD: NOT AVAILABLE.
DISPERSION PROPERTIES: NOT AVAILABLE. OTHER PREC: INTENTIONAL
MISUSE BY DELIBERATELY CONCENTRATING AND INHALING THE CONTENTS CAN
BE HARMFUL OR FATAL.

Chemical Properties

Boiling Pt:<-17.6C, 0.F
B.P. Text:<0- -9F
Vapor Pres:SEE INGREDS
Vapor Density:>1 (AIR=1)
Spec Gravity:0.8
Appearance and Odor:FAINT ETHERAL; CLEAR COLORLESS GAS.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:BY FIRE: CARBON DIOXIDE, CARBON
MONOXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:WASTE FROM THIS PRODUCT MAY BE HAZARDOUS AS
DEFINED UNDER THE RESOURCE CONSERVATION AND RECOVERY AT (RCRA) 40
CFR 261. WASTE MUST BE TESTED FOR IGNITABILITY TO DETERMINED THE
APPLICABLE EPA HAZARDOUS WASTE NUMBERS. DO NOT INCINERATE.
DEPRESSURIZE CONTAINER. DISPOSE OF IN ACCORDANCE WITH FEDERAL, STA
TE, AND LOCAL REGULATIONS REGARDING POLLUTION.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Regulatory

SARA Title III Information:SARA 313 SUPPLIER NOTIFICATION: NO
INGREDIENTS IN THIS PRODUCT ARE SUBJECT TO SARA 313 OF SARA (40 CFR
372.65C).
Federal Regulatory Information:TSCA CERTIFICATION: ALL CHEMICALS IN
THIS PRODUCT ARE LISTED, OR ARE EXEMPT FROM LISTING, ON THE TSCA
INVENTORY.