CKRNH - DAP KWIK FOAM
- MSDS: CKRNH
- Manufacturer: DAP INC
- Product Name: DAP KWIK FOAM
- National Stock Number: 8030-01-324-1376
Product Identification
Product ID:DAP KWIK FOAM
MSDS Date:09/14/1989
FSC:8030
NIIN:01-324-1376
Status Code:A
MSDS Number: CKRNH
Responsible Party
DAYTON, OH 45401-0277
US
Emergency Phone: 800-543-3840, 513-236-0911
Info Phone: 513-253-7154, 513-236-0911
Cage: 90300
Contractor
Telephone: 513-253-7154/800-543-3840
Cage: 90300
Ingredients
METHYLENE BISPHENYL ISOCYANATE (MDI) (CONTAINS HIGHER
CAS: 101-68-8
RTECS: NQ9350000
Fraction By Weight: <30%
OSHA PEL C, 0.02 PPM
ACGIH TLV: 0.005 PPM; 9293
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
HYDROGENATED CHLOROFLUOROALKANE
Fraction By Weight: 15-30%
REMAINING TRADE SECRET, NON-HAZARDOUS INGREDIENTS. (NOT
Hazards
LD50 LC50 Mixture:ORAL LD50 (RAT) IS UNKNOWN.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES/SKIN/INGESTION: IRRITATION.
INHALATION: RESPIRATORY IRRITATION, LIGHT HEADEDNESS, CARDIAC
IRREGULARITIES.
Effects of Overexposure:EYES/SKIN/INGESTION: IRRITATION. INHALATION:
RESPIRATORY IRRITATION, LIGHT HEADEDNESS, CARDIAC IRREGULARITIES.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES: FLUSH WITH LARGE AMOUNTS OF WATER. IF IRRITATION
PERSISTS GET MEDICAL ATTENTION. SKIN: REMOVE CONTAMINATED CLOTHING.
WASH AREA WITH SOAP AND WATER. IF IRRITATION PERSISTS, GET MEDICAL
ATTENTION. INHALATION: MOVE TO FRESH AIR. IF ADVERSE SYMPTOMS
DEVELOP, GET MEDICAL ATTENTION. INGESTION: DO NOT INDUCE VOMITING.
GET MEDICAL ATTENTION.
Fire Fighting
Flash Point Method:CC
Flash Point:NONE
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICALS.
Fire Fighting Procedures:USE WATER SPRAY TO COOL FIRE EXPOSED SURFACES.
Unusual Fire/Explosion Hazard:CONTAINERS DEVELOP PRESSURE WHEN HEATED.
Accidental Release
Spill Release Procedures:VENTILATE AREA. COLLECT IN OPEN CONTAINERS
AFTER PRODUCT HAS CURED.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE AWAY FROM CAUSTICS, OXIDIZERS,
EXCESSIVE HEAT AND FREEZING. KEEP CONTAINERS TIGHTLY CLOSED WHEN
NOT IN USE. KEEP OUT OF REACH OF CHILDREN.
Other Precautions:VAPORS ARE HEAVIER THAN AIR AND WILL COLLECT IN LOW
AREAS. CHECK ALL LOW AREAS (BASEMENTS, SUMPS, ETC.) FOR VAPOR
BEFORE ENTERING.
Exposure Controls
Respiratory Protection:USE APPROVED NIOSH/MSHA RESPIRATOR IF
ESTABLISHED EXPOSURE LIMIT IS EXCEEDED FOR ANY COMPONENT.
Ventilation:PROVIDE SUFFICIENT MECHANICAL (GENERAL) OR LOCAL EXHAUST TO
MAINTAIN EXPOSURE BELOW PEL AND TLV.
Protective Gloves:RECOMMENDED FOR PROLONGED EXPOSURE.
Eye Protection:WEAR SAFETY GOGGLES.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
Chemical Properties
HCC:V2
Boiling Pt:B.P. Text:0F,-18C
Vapor Density:8.5 (MDI)
Spec Gravity:1.2
Solubility in Water:REACTS
Appearance and Odor:VISCOUS LIQUID. FOAMS WHEN RELEASED FROM
PRESSURIZED CONTAINER.
Stability
Stability Indicator/Materials to Avoid:YES
ALCOHOLS, WATER, STRONG BASES, AMINES, METAL COMPOUNDS.
Stability Condition to Avoid:EXCESSIVE HEAT. STABLE AT ROOM
TEMPERATURE. HAZARDOUS POLYMERIZATION MAY OCCUR AT HIGH
TEMPERATURES.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
NITROGEN OXIDES, TRACES OF HYDROGEN CYANIDE.
Conditions to Avoid Polymerization:STABLE AT ROOM TEMPERATURE.
HAZARDOUS POLYMERIZATION MAY OCCUR AT HIGH TEMPERATURES.
Disposal
Waste Disposal Methods:DISPOSE OF WASTE IN ACCORDANCE WITH LOCAL, STATE
AND FEDERAL REGULATIONS. THIS PRODUCT IS NON-HAZARDOUS ACCORDING TO
U.S. EPA'S HAZARDOUS WASTE MANAGEMENT REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their