CLFJF - 89-2261,HEMATOXYLIN, DELAFIELD
- MSDS: CLFJF
- Manufacturer: CAROLINA BIOLOGICAL SUPPLY CO
- Product Name: 89-2261,HEMATOXYLIN, DELAFIELD
- National Stock Number: -
Product Identification
Product ID:89-2261,HEMATOXYLIN, DELAFIELD
MSDS Date:09/05/2000
FSC:NIIN:Submitter:D DG
Status Code:A
Kit Part:Y
MSDS Number: CLFJF
Responsible Party
BURLINGTON, NC 27215-3387
US
Emergency Phone: 800-227-1150
Info Phone: 800-227-1150/910-584-0381
Cage: 59896
Contractor
Telephone: 800-227-1150/910-584-0381
Cage: 59896
Ingredients
METHANOL
CAS: 67-56-1
RTECS: PC1400000
OSHA PEL 260 MG/M3;200 PPM
ACGIH TLV: 262 MG/M3;200 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
GLYCERIN
CAS: 56-81-5
RTECS: MA8050000
OSHA PEL 15 MG/M3
ACGIH TLV: 10 MG/M3
ALUMINUM POTASSIUM SULFATE
CAS: 10043-67-1
RTECS: WS5650000
ETHANOL
CAS: 64-17-5
RTECS: KQ6300000
OSHA PEL 1900 MG/M3;1000 PPM
ACGIH TLV: 1880 MG/M3;1000 PPM
GLACIAL ACETIC ACID
CAS: 64-19-7
RTECS: AF1225000
OSHA PEL 25 MG/M3;10 PPM
ACGIH TLV: 25 MG/M3;10 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
HAEMATOXYLIN
CAS: 517-28-2
RTECS: MH7875000
MERCURY OXIDE
CAS: 21908-53-2
RTECS: OW8750000
OSHA PEL SEE TABLE Z-2
ACGIH TLV: 0.025 MG/M3
Hazards
LD50 LC50 Mixture:ORL-RAT LD50: 5,628MG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MERCURY AND ITS COMPOUNDS MAY BE QUITE
TOXIC EVEN IN SMALL AMOUNTS THROUGH ALL ROUTES OF ENTRY. EYES: MAY
CAUSE IRRITATION. SKIN: MAY CAUSE IRRITATION. INGESTION: MAY CAUSE
GASTROINTESTINAL DISCOMFORT . INHALATION: MAY CAUSE IRRITATION TO
RESPIRATORY TRACT.
Explanation of Carcinogenicity:NOT LISTED AS CAUSING CANCER BY IARC,
NTP OR OSHA.
Effects of Overexposure:MERCURY AND ITS COMPOUNDS MAY BE QUITE TOXIC
EVEN IN SMALL AMOUNTS THROUGH ALL ROUTES OF ENTRY. EYES: MAY CAUSE
IRRITATION. SKIN: MAY CAUSE IRRITATION. INGESTION: MAY CAUSE
GASTROINTESTINAL DISCOMFORT . INHALATION: MAY CAUSE IRRITATION TO
RESPIRATORY TRACT.
First Aid
First Aid:EYES: FLUSH WITH WATER 15 MINUTES, RAISING AND LOWERING
EYELIDS. GET MEDICAL ATTENTION IF IRRITATION PERSISTS. SKIN: WASH
EXPOSED AREA 15 MINUTES. REMOVE, LAUNDER, CONTAMINATED CLOTHING
BEFORE REUSE. GET MEDICAL ATTENTION IF IRRITATION. INGESTION: IF
SWALLOWED, IF CONSCIOUS, GIVE PLENTY OF WATER AND INDUCE VOMITING
IMMEDIATELY, DIRECTED BY MEDICAL PERSONNEL. IMMEDIATELY CALL
PHYSICIAN OR POISON CO NTROL CENTER. NEVER GIVE ANYTHING BY MOUTH
TO UNCONSCIOUS PERSON. INHALATION: REMOVE TO FRESH AIR. GIVE OXYGEN
IF BREATHING DIFFICULT. GIVE ARTIFICIAL RESPIRATION IF BREATHING
HAS STOPPED. KEEP PERSON WARM, QUIET, GET MEDICAL ATTENTION.
Fire Fighting
Lower Limits:3.3
Upper Limits:19
Extinguishing Media:USE MEDIA SUITABLE TO EXTINGUISH SURROUNDING FIRE.
Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR FULL PROTECTIVE
EQUIPMENT AND NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:DUE TO THE LOW CONCENTRATION OF FLAMMABLE
CONSTITUENTS IN THIS MIXTURE IT IS NOT EXPECTED TO BE A SIGNIFICANT
FIRE HAZARD. HOWEVER, UNDER CONDITIONS OF INCREASED PRESSURE AND
HEAT, CONTAINERS MAY EXPL ODE.
Accidental Release
Spill Release Procedures:VENTILATE AREA OF SPILL. ELIMINATE ALL SOURCES
OF IGNITION. REMOVE ALL NON-ESSENTIAL PERSONNEL FROM AREA. CLEAN-UP
PERSONNEL SHOULD WEAR PROPER PROTECTIVE EQUIPMENT AND CLOTHING.
ABSORB MATERIAL WITH SUITABLE ABSORBENT AND CONTAINERIZE FOR
DISPOSAL.
Handling
Handling and Storage Precautions:STORE TIGHTLY CLOSED IN A COOL, DRY
WELL VENTILATED AREA SUITABLE FOR FLAMMABLE LIQUID STORAGE. DO NOT
BREATHE FUMES. DO NOT GET IN EYES, ON SKIN OR ON CLOTHING.
Other Precautions:DO NOT TAKE INTERNALLY. WASH THOROUGHLY AFTER
HANDLING.
Exposure Controls
Respiratory Protection:A NIOSH/MSHA CHEMICAL CARTRIDGE RESPIRATOR
SHOULD BE WORN IF PEL OR TLV IS EXCEEDED.
Ventilation:LOCAL EXHAUST: YES MECHANICAL (GENERAL): YES
Protective Gloves:RUBBER, NEOPRENE, PVC, OR EQUIVALENT.
Eye Protection:SPLASH PROOF CHEMICAL SAFETY GOGGLES SHOULD BE WORN AT
ALL TIMES.
Other Protective Equipment:LAB COAT, EYE WASH, AND SAFETY SHOWER.
Supplemental Safety and Health
THIS MSDS IS FOR ONE PART OF A KIT (CK-BASIC STAIN SET / ITEM 89-2261).
THE HMIS SERIAL NUMBERS FOR ALL PARTS OF THIS KIT (INCLUDING THE
ONE FOR THIS MSDS) ARE: CLFHF, CLFHH, CLFHK, CLFJF, CLFJG, AN D
CLFJJ.
Chemical Properties
HCC:F3
Boiling Pt:B.P. Text:NO DATA AVAILABLE
Melt/Freeze Pt:M.P/F.P Text:NO DATA AVAILABLE
Decomp Temp:Decomp Text:NO DATA AVAILABLE
Solubility in Water:COMPLETE
Appearance and Odor:REDDISH PURPLE SOLUTION, SLIGHT ODOR OF VINEGAR.
Stability
Stability Indicator/Materials to Avoid:YES
WATER REACTIVE MATERIALS, STRONG OXIDIZERS.
Stability Condition to Avoid:STABLE. EXCESSIVE HEAT.
Hazardous Decomposition Products:IF HEATED TO DECOMPOSITION THIS
PRODUCT MAY EMIT HIGHLY TOXIC FUMES OF MERCURY.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS. ALWAYS CONTACT A PERMITTED
WASTE DISPOSER (TSD) TO ASSURE COMPLIANCE.
Toxicology
Toxicological Information:METHANOL: ORL-RAT LD50: 5,628 MG/MG, IHL-RAT
LC50: 64,000 PPM/4H. GLYCERIN: ORL-RAT LD50: 12,600 MG/KG.
ALUMINUM POTASSIUM SULFATE: NOT TOXICITY DATA AVAILABLE. ETHANOL:
ORL-RAT LD50: 7,060 MG/KG, IHL-RAT LC50: 20,000 PPM/10H. GLACIAL
ACETIC ACID: IHL-RAT LCLO: 16,000 PPM/4H, ORL-RAT LD50: 20,000
MG/KG. HEMATOXYLIN: NO TOXIC EFFECTS DATA FOUND. MERCURIC OXIDE:
ORL-RAT LD50: 18 MG/KG, SKN-RAT LD50: 315 MG/KG.
Ecology
Ecological:EPA WASTE NUMBERS: METHANOL U154; ETHANOL D001; GLACIAL
ACETIC ACID D002; MERCURY U151, D009.
Transport
Transport Information:DESCRIPTION: FLAMMABLE LIIQUID, NOS (METHANOL,
ETHANOL, GLACIAL ACETIC ACID), 3, UN1993, III.
Regulatory
SARA Title III Information:HAZARD CATEGORY FOR SARA SECTION 311/312
REPORTING: ACUTE. METHANOL IS ON SARA SEC. 313 CHEMICALS LIST.
Federal Regulatory Information:EPA TSCA STATUS: ON TSCA INVENTORY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.