Product ID:RHODORSIL FLUID 47V50
MSDS Date:04/01/1996
FSC:9150
NIIN:00-292-9609
Status Code:A
MSDS Number: CLLNP
Responsible Party
CRANBURY, NJ 08512-7500
US
Emergency Phone: 800-334-7577
Info Phone: 609-860-4000/800-356-7560
Cage: LO755
Contractor
Telephone: 609-860-4000/800-356-7560
Cage: LO755
Ingredients
POLY(DIMETHYL)SILOXANE
Hazards
LD50 LC50 Mixture:LDL0, RAT: >5000 MG/KG.
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE EYE: SLIGHTLY IRRITATING. MAY
CAUSE REDNESS, IRRITATION. ACUTE SKIN: NON-IRRITATING. LOW ACUTE
DERMAL TOXICITY. ACUTE INHALATION: INHALATION NOT LIKELY. ACUTE
INGESTION: LOW ACUTE ORAL TOXICITY. CHRONIC EFFECTS: THIS PRODUCT
DOES NOT CONTAIN ANY INGREDIENT DESIGNATED BY IARC, NTP, AGGIH OR
OSHA AS PROBABLE OR SUSPECTED HUMAN CARCINOGENS.
Explanation of Carcinogenicity:PRODUCT CONTAINS DIMETHYLPOLYSILOXANE
WHICH CAN GENERATE FORMALDEHYDE AS A BYPRODUCT OF THERMAL
DECOMPOSITION. EXPOSURE TO FORMALDEHYDE CAN CAUSE ADVERSE EFEFCTS
SUCH AS SKIN & RESPIRATORY SENSITIZAT ION AND IS A POTENTIAL CANCER
HAZARD. PRODUCT DOES NOT CONTAIN ANY INGREDIENT DESIGNATED BY
IARC, NTP, AGGIH OR OSHA AS PROBABLE OR SUSPECTED CARCINOGENS.
Effects of Overexposure:ACUTE EYE: SLIGHTLY IRRITATING. MAY CAUSE
REDNESS, IRRITATION. ACUTE SKIN: NON-IRRITATING. LOW ACUTE DERMAL
TOXICITY. ACUTE INHALATION: INHALATION NOT LIKELY. ACUTE INGESTION:
LOW ACUTE ORAL TOXICITY.
Medical Cond Aggravated by Exposure:NO SPECIFIC INFORMATION FOUND.
First Aid
First Aid:EYE EXPOSURE: IN CASE OF CONTACT, IMMEDIATELY ABSORB EXCESS
WITH CLEAN ABSORBENT CLOTH OR COTTON. HOLD LIDS OPEN & FLUSH WITH A
WATER FOR AT LEAST 15 MINUTES. SEEK MEDICAL ATTENTION IF IRRITATION
PERS ISTS OR IF VISUAL CHANGES OCCUR. SKIN EXPOSURE: IMMEDIATELY
WIPE EXCESS MATERIAL OFF WITH A DRY CLOTH; THEN WASH WITH PLENTY OF
WATER. SEEK MEDICAL ATTENTION IF IRRITATION DEVELOPS OR PERSISTS.
INHALA TION: IF DISTRESS OCCURS REMOVE VICTIM TO FRESH AIR. SEEK
MEDICAL ATTENTION IF RESPIRATORY IRRITATION OR DISTRESS CONTINUES.
INGESTION: IF VICTIM IS CONSCIOUS AND ALERT, GIVE 1-2 GLASSES
WATER. NOTHIN G BY MOUTH IF UNCONSCIOUS.
Fire Fighting
Flash Point:=299.C, 570.2F
Lower Limits:NO DATA
Upper Limits:NO DATA
Extinguishing Media:RECOMMENDED: DRY CHEMICAL, FOAM, CARBON DIOXIDE.
Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR NIOSH/MSHA APPROVED
SELF-CONTAINED BREATHING APPARATUS AND FULL PROTECTIVE CLOTHING.
COOL CONTAINERS EXPOSED TO FIRE WITH WATER.
Unusual Fire/Explosion Hazard:PRODUCT WILL BURN UNDER FIRE CONDITIONS.
Accidental Release
Spill Release Procedures:FOLLOW PROCEDURE DESCRIBED BELOW UNDER CLEANUP
AND DISPOSAL OF SPILL. ABSORB WITH AN INERT ABSORBENT. SCRAPE UP
AND PLACE IN APPROPRIATE CLOSED CONTAINER. CLEAN UP RESIDUAL
MATERIAL WITH AN APPROPRIAT E SOLVENT LIKE PAINT THINNER OR MINERAL
SPIRITS, PROVIDED THAT THERE IS GOOD VENTILATION AND NO SOURCES OF
IGNITION. DO NOT FLUSH TO DRAIN.
Neutralizing Agent:NO DATA PROVIDED BY MANUFACTURER
Handling
Handling and Storage Precautions:MINIMUM/MAXIMUM STORAGE TEMPERATURE:
NOT AVAILABLE. HANDLING: AVOID BREATHING VAPORS AND MISTS. AVOID
DIRECT OR PROLONGED CONTACT WITH SKIN AND EYES. STORE IN TIGHTLY
CLOSED CONTAINERS. STORE IN AN AR EA THAT IS DRY, WELL-VENTILATED,
AWAY FROM INCOMPATIBLE MATERIAL.
Other Precautions:NO DATA PROVIDED BY MANUFACTURER
Exposure Controls
Respiratory Protection:WHEN RESPIRATORS ARE REQUIRED, SELECT NIOSH/MSHA
APPROVED EQUIPMENT BASED ON ACTUAL OR POTENTIAL AIRBORNE
CONCENTRATIONS AND IN ACCORDANCE WITH THE APPROPRIATE REGULATORY
STANDARDS AND/OR INDUSTRIAL R ECOMMENDATIONS.
Ventilation:WHERE ENGINEERING CONTROLS ARE INDICATED BY USE CONDITIONS
OR A POTENTIAL FOR EXCESSIVE EXPOSURE EXISTS, THE FOLLOWING
TRADITIONAL EXPOSRE CONTROL TECHNIQUES
Protective Gloves:GLOVES ARE RECOMMENDED.
Eye Protection:EYE AND FACE PROTECTION REQUIREMENTS WILL VARY DEPENDENT
UPON WORK ENVIRONMENT
Other Protective Equipment:SKIN CONTACT SHOULD BE MINIMIZED THROUGH USE
OF GLOVES AND SUITABLE LONG-SLEEVED CLOTHING (I.E., SHIRTS AND
PANTS). COSIDERATION MUST BE GIVEN BOTH TO DURABILITY AS WELL AS
PERMEATION RESISTANCE.
Work Hygienic Practices:PERSONAL HYGIENE IS AN IMPORTANT WORK PRACTICE
EXPOSURE CONTROL MEASURE AND THE FOLLOWING GENERAL MEASURES SHOULD
BE TAKEN WORKING WITH OR HANDLING THIS MATERIAL.
Supplemental Safety and Health
NO DATA PROVIDED BY MANUFACTURER.
Chemical Properties
HCC:V5
Boiling Pt:B.P. Text:NOT AVAILABLE
Melt/Freeze Pt:M.P/F.P Text:NOT AVAILABLE
Vapor Pres:<0.01 MMHG AT 20C (68)
Spec Gravity:0.96 AT 25 C (77F)
Viscosity:50 CS AT 25 C (77F).
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR VISCOUS LIQUID , ODORLESS.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG BASES, STRONG ACIDS, STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT, OPEN FLAME SPARK, STATIC
ELECTRICITY.
Hazardous Decomposition Products:NO DATA PROVIDED BY MANUFACTURER
Disposal
Waste Disposal Methods:CHEMICAL ADDITIONS, PROCESSING OR OTHERWISE
ALTERING THIS MATERIAL MAY MAKE THE WASTE MANAGEMENT INFORMATION IN
THIS MSDS INCOMPLETE, INACCURATE OR OTHERWISE INAPPROPRIATE. PLEASE
BE ADVISED THAT STAT E AND LOCAL REQUIREMENTS MAY BE MORE
RESTRICTIVE THAN FEDERAL LAWS & REGULATIONS.
Toxicology
Toxicological Information:ACUTE EYE IRRITATION: EYE-EYE IRRITATION,
RABBIT. SLIGHTLY IRRITATING. ACUTE SKIN IRRITATION: SKIN-SKIN
IRRITATION, RABBIT. NON-IRRITATING. ACUTE DERMAL TOXICITY: NO TEST
DATA FOUND FOR PRODUCT. ACUTE RESPIRATORY IRRITATION: NO TEST DATA
FOUND FOR PRODUCT. ACUTE INHALATION TOXICITY: NO TEST DATA FOUND
FOR PRODUCT. ACUTE ORAL TOXICITY: LDLO: LOWEST LETHAL DOSE, > 5000
MG/KG, RAT. NO DEATHS OBSERVED .
Other Information
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ecology
Ecological:ECOTOXICOLOGICL INFORMATION: NO DATA FOUND FOR PRODUCT.
CHEMICAL FATE INFORMATION: NO DATA FOUND FOR PRODUCT.
Transport
Transport Information:NOT REGULATED.
Regulatory
SARA Title III Information:SARA TITLE III HAZARD CLASSES: FIRE HAZARD:
NO; REACTIVE HAZARD: NO; RELEASE OF PRESSURE: NO; ACUTE HEALTH
HAZARD: NO; CHRONIC HEALTH HAZARD: NO.
Federal Regulatory Information:ALL FUNCTIONAL COMPONENTS OF THIS
PRODUCT ARE LISTED ON THE TSCA INVENTORY.
State Regulatory Information:THIS PRODUCT DOES NOT CONTAIN ANY
COMPONENTS THAT ARE REGULATED UNDER CALIFORNIA PROPOSITION 65.