EEEIW - 2-BUTENE

Product Identification

Product ID:2-BUTENE
MSDS Date:Jul 13 2000
MSDS Number: EEEIW
Kit Part:=== Responsible Party ===
Company Name:MATHESON TRI-GAS, INC.
Address:959 ROUTE 46 EAST
City:PARSIPPANY
State:NJ
ZIP:07054-0624
Country:US
Info Phone Num:(USA) 973-257-1100, (WHITBY) 905-668-3570, (EDMONTON)
780-471-4036
Chemtrec Ind/Phone:18004249300

Contractor
MATHESON TRI-GAS, INC.
WHITBY, L1N 5R9 07054-0624 ONTARIO, CANADA

Telephone: (USA) 973-257-1100, (WHITBY) 905-668-3570, (EDMONTON)

Ingredients

2-BUTENE

CAS: 107-01-7

Fraction By Weight: 100.0%

Hazards

Reports of Carcinogenicity:NTP:No IARC:No OSHA:No
Medical Cond Aggravated by Exposure:

First Aid

First Aid: INHALATION: If adverse effects occur, remove to
uncontaminated area. Give artificial respiration if not breathing.
If breathing is difficult, oxygen should be administered by
qualified personnel. Get immediate medical attention. SKIN CONTACT:
If frostbite or freezing occur, immediately flush with plenty of
lukewarm water (105-115 F; 41-46 C). DO NOT USE HOT WATER. If warm
water is not available, gently wrap affected parts in blankets. Get
immediate medical attention. EYE CONTACT: Contact with liquid:
Immediately flush eyes with plenty of water for at least 15
minutes. Then get immediate medical attention. INGESTION: If a
large amount is swallowed, get medical attention. NOTE TO
PHYSICIAN: For inhalation, consider oxygen.

Fire Fighting

Flash Point:<-29 F (<-34 C)
Autoignition Temp:595 F (313 C)
Lower Limits:1.7%
Upper Limits:9.3%
Extinguishing Media:carbon dioxide, regular dry chemical Large fires:
Flood with fine water spray.
Fire Fighting Procedures:Move container from fire area if it can be
done without risk. Cool containers with water spray until well
after the fire is out. Stay away from the ends of tanks. For fires
in cargo or storage area: Cool containers with water from unmanned
hose holder or monitor nozzles until well after fire is out. If
this is impossible then take the following precautions: Keep
unnecessary people away, isolate hazard area and deny entry. Let
the fire burn. Withdraw immediately in case of rising sound from
venting safety device or any discoloration of tanks due to fire.
For tank, rail car or tank truck: Stop leak if possible without
personal risk. Let burn unless leak can be stopped immediately. For
smaller tanks or cylinders, extinguish and isolate from other
flammables. Evacuation radius: 800 meters (1/2 mile). Do not
attempt to extinguish fire unless flow of material can be stopped
first. Flood with fine water spray. Cool containers with water
spray until well after the fire i out. Apply water from a protected
location or from a safe distance. Avoid inhalation of material or
combustion by-products. Stay upwind and keep out of low areas.
Evacuate if fire gets out of control or containers are directly
exposed to fire. Evacuation radius: 500 meters (1/3 mile). Consider
downwind evacuation if material is leaking. Stop flow of gas.
Unusual Fire/Explosion Hazard:Severe fire hazard. The vapor is heavier
than air. Vapors or gases may ignite at distant ignition sources
and flash back. Electrostatic discharges may be generated by flow
or agitation resulting in ignition or explosion. Gas/air mixtures
are explosive. Containers may rupture or explode if exposed to
heat.

Accidental Release

Spill Release Procedures:Avoid heat, flames, sparks and other sources
of ignition. Do not touch spilled material. Stop leak if possible
without personal risk. Reduce vapors with water spray. Keep
unnecessary people away, isolate hazard area and deny entry. Remove
sources of ignition. Ventilate closed spaces before entering.
Neutralizing Agent:

Handling

Handling and Storage Precautions:Store and handle in accordance with
all current regulations and standards. Avoid contact with
temperatures above 52 C. Do not puncture or burn containers, even
when empty. Store in a tightly closed container. Store in a
well-ventilated area. Subject to storage regulations: U.S. OSHA 29
CFR 1910.101. Keep separated from incompatible substances.
Other Precautions:

Exposure Controls

Respiratory Protection:Under conditions of frequent use or heavy
exposure, respiratory protection may be needed. Respiratory
protection is ranked in order from minimum to maximum. Consider
warning properties before use. For Unknown Concentrations or
Immediately Dangerous to Life or Health - Any supplied-air
respirator with full facepiece and operated in a pressure-demand or
other positive-pressure mode in combination with a separate escape
supply. Any self-contained breathing apparatus with a full
facepiece.
Ventilation:Ventilation equipment should be explosion-resistant if
explosive concentrations of material are present. Provide local
exhaust or process enclosure ventilation system. Ensure compliance
with applicable exposure limits.
Protective Gloves:Wear insulated gloves.
Eye Protection:Wear splash resistant safety goggles with a faceshield.
Provide an emergency eye wash fountain and quick drench shower in
the immediate work area.
Other Protective Equipment:For the gas: Protective clothing is not
required. For the liquid: Wear appropriate protective, cold
insulating clothing.
Supplemental Safety and Health
2-BUTENE: No occupational exposure limits established.

Chemical Properties

Boiling Pt:34-39 F (1-4 C)
Melt/Freeze Pt:-220 to -218 F (-140 to -139 C)
Vapor Pres:Not available
Vapor Density:1.9
pH:Not applicable
Evaporation Rate & Reference:Not applicable
Solubility in Water:insoluble
Appearance and Odor:PHYSICAL STATE:gas COLOR:colorless ODOR:Not
available
Corrosion Rate:

Stability

Stability Indicator/Materials to Avoid:Stable at normal temperatures
and pressure.
Stability Condition to Avoid:Avoid heat, flames, sparks and other
sources of ignition. Minimize contact with material. Containers may
rupture or explode if exposed to heat.
Hazardous Decomposition Products:Thermal decomposition products or
combustion: oxides of carbon Thermal decomposition products or
combustion: oxides of carbon
Conditions to Avoid Polymerization:Will not polymerize.

Disposal

Waste Disposal Methods:Dispose in accordance with all applicable
regulations. Subject to disposal regulations: U.S. EPA 40 CFR 262.
Hazardous Waste Number(s): D001.

Toxicology

Toxicological Information:2-BUTENE: TOXICITY DATA: 425 ppm
inhalation-mouse LC50 ACUTE TOXICITY LEVEL: Toxic: inhalation

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ecology

Ecological:Not available

Transport

Transport Information:U.S. DOT 49 CFR 172.101: PROPER SHIPPING NAME:
Compressed gas, toxic, flammable, n.o.s. Inhalation hazard Zone B
(2-BUTENE) ID NUMBER: UN1953 HAZARD CLASS OR DIVISION: 2.3 LABELING
REQUIREMENTS: Poison gas; Flammable gas QUANTITY LIMITATIONS:
PASSENGER AIRCRAFT OR RAILCAR: Forbidden CARGO AIRCRAFT ONLY:
Forbidden

Regulatory

SARA Title III Information: SARA TITLE III SECTION 302 EXTREMELY
HAZARDOUS SUBSTANCES (40 CFR 355.30): Not regulated. SARA TITLE
III SECTION 304 EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355.40): Not
regulated. SARA TITLE III SARA SECTIONS 311/312 HAZARDOUS
CATEGORIES (40 CFR 370.21): ACUTE: Yes CHRONIC: No FIRE: Yes
REACTIVE: No SUDDEN RELEASE: Yes SARA TITLE III SECTION 313 (40
CFR 372.65): Not regulated.
Federal Regulatory Information:CERCLA SECTIONS 102a/103 HAZARDOUS
SUBSTANCES (40 CFR 302.4): Not regulated. OSHA PROCESS SAFETY
(29CFR1910.119): Not regulated.
State Regulatory Information: California Proposition 65: Not regulated.